User Guide
FUNCTIONAL DESCRIPTION
FRONT PANEL
Keypad
SET To display
setpoint
MEAS To display
measurement
Trimmers
CAL For pH Offset
Calibration
SET To adjust the
Setpoint
LEDs
SET ON when LCD
displays the set value
MEAS ON when the LCD displays the measurement
value
DOSING ON when dosing contact is activated
REAR PANEL
1. Power Supply:
HI 981411-0 HI 981411-1
12VDC 115/230 VAC
L1: Positive 230 VAC
L2: Negative 115 VAC
L3: ------ Neutral
L4: ------ Protection Earth
Note: the power input is internally protected by a 400 mA fuse.
2.Dosing Selection Contacts:
Leave S1 and S2 open to select ACID dosage;
Short S1 and S2 to select ALKALINE dosage.
3.The dosing (alarm) contact acts as a switch. The
contact has to be protected outside by the user.
HI 981411
pH CONTROLLER
SET
MEAS
SET
DOSING
CAL
pH
0.0 ...14.0 pH
OPERATIONAL GUIDE
POWER CONNECTION
HI 981411-0
Connect a 2-wire power cable to the terminal strip while
paying attention to the correct positive and negative con-
tacts (12VDC).
HI 981411-1
Connect a 3-wire power cable to the terminal strip while
paying attention to the correct earth, neutral and line
contacts (115/230 VAC).
Notes:
• All external cables connected to the rear panel should
end with wire lugs.
• It is recommended to cover the unused terminals with
insulating tape.
• At start up the meter needs a few seconds to stabilize.
Wait until a stable reading is displayed.
DOSING CONTACT
This contact (maximum 5A, 240VAC, 30VDC) is used for
connection to an alarm or dosing system. The relay contact
acts as a power switch for the controlling device.
OPERATING THE METER
All settings of the parameters can be controlled via front
panel keys and trimmers. “SET” and “MEAS” LEDs light up
to indicate which is the operating function.
Make sure that the meter is calibrated and that the
Setpoint is properly adjusted before proceeding.
Attach the pH-electrode to the meter with a BNC connector.
Install the electrode in the fittings or immerse it in the
solution to be monitored. Press the "MEAS" key.
The LCD will show the pH value. Any initial variation on
readings may be due to temperature compensation.
The “DOSING” LED will light up when the dosing contact is
closed.
CALIBRATION
Make sure the meter is in the measurement mode (the
“MEAS” LED lights on). Immerse the electrode in HI 7007
(pH7.01) buffer solution (or any buffer solution close to the
operating pH value). Shake briefly and wait for reading to
stabilize. Adjust the calibration trimmer until “7.0” is
displayed on the LCD.
SETPOINT
Press the "SET" key. The display will show the default or
previously adjusted value. Using a small screwdriver adjust
Front view of the
panel-mounted unit
Side view of the
panel-mounted unit
Supplied adjustable lo-
cation brackets allow
the controller to slide
into the cutout and will
hold the unit securely
in place. 95mm (3.74")
is the minimum amount
of space required to
install the controller.
Panel-mounted unit assembling view
73mm
2.87"
79mm
3.11"
42mm
1.65"
49mm
1.93"
95mm MIN
3.74"
76mm
3"
0.25/4mm
0.01/0.160"
79mm
3.11"
ADJUSTABLE
LOCATION
BRACKET
HI981411 LAYOUT
HI 740146
ACCESSORIES
pH CALIBRATION SOLUTIONS
HI 7007M pH 7.01 Buffer Solution, 230mL bottle
HI 7007L pH 7.01 Buffer Solution, 460mL bottle
ELECTRODE STORAGE SOLUTION
HI 70300M Storage Solution, 230mL bottle
ELECTRODE CLEANING SOLUTIONS
HI 7061M General Cleaning Solution, 230mL bottle
HI 7061L Oil & Fat Cleaning Solution, 230mL bottle
pH ELECTRODES
HI1002/5 Heavy-duty BNC-type double junction, plastic-
body with external thread and 5m (16.5’) cable
HI1090T Screw type, double junction, glass-body with
external thread
HI1110S Screw type, single junction, glass-body
HI1210T Screw type, double junction, plastic-body with
external thread
HI2114P/2 BNC-type, double junction plastic-body with
2m (6.6’) cable
HI1210B/5 BNC-type cable, double junction, plastic-body,
with 5 m (16.5') cable
HI2910B/5 BNC-type, double junction, plastic-body, built-
in amplifier, with 5 m (16.5') cable
EXTENSION CABLES FOR SCREW-TYPE ELECTRODES
TO BNC CONNECTOR
HI7855/5 Extension cable 5m (16.5') long
HI7855/10 Extension cable 10m (33') long
OTHER ACCESSORIES
BL PUMPS Dosing Pumps with flow rate from 1.5 to 20 LPH
HI6050 Submersible electrode holder, 60cm (24”)
HI 6051 Submersible electrode holder, 110cm (43”)
HI 6054B Electrode Holders for in-line applications
HI 6054T Electrode Holders for in-line applications
HI 710005 12 VDC power adapter, US plug
HI 710006 12 VDC power adapter, European plug
HI 710012 12 VDC power adapter, Australian plug
HI 710013 12 VDC power adapter,Southern Africa plug
HI 710014 12 VDC power adapter, UK plug
HI731326 Calibration Screwdriver (20 pcs)
HI 7871 Level Controller (min and max)
HI 7873 Level Controller (min, max and overflow)