Instruction Manual HI9063 - HI91530K HI91531K - HI91532K Portable Waterproof Microprocessor K-Type Thermocouple Thermometers http://www.hannainst.
Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with directives EN 50081-1 and EN 50082-1.
FUNCTIONAL DESCRIPTION HI9063 1 CHANNEL THERMOMETER FUNCTIONAL DESCRIPTION HI91530K 1 CHANNEL THERMOMETER 1 1 ins rum n s ins rum n s °C 2 HI °C 2 K HI 91530K microprocessor K-thermocouple thermometer HI 9063 microcomputer K-thermocouple thermometer -50 . . . . . +150°C -58 . . . . . +302°F -50 . . . . . +950°C -58 . . . . . +1742°F 5 4 RANGE -200.0 . . . . . 1370°C -300.0 . . . . .
FUNCTIONAL DESCRIPTION H HII 91531K 1 CHANNEL THERMOMETER FUNCTIONAL DESCRIPTION HI91532K 2 CHANNELS THERMOMETER 1 1 2 ins rum n s ins rum n s °C 2 °C K 3 K HI 91531K microprocessor K-thermocouple thermometer HI 91532K MICROPROCESSOR DUAL INPUT K-THERMOCOUPLE °C THERMOMETER RANGE -200.0 . . . . . 1370°C --300.0 . . . . . 2500°F 3 5 RANGE -200.0 . . . . .
RESOLUTION (HI 9063 AND HI 91532K ONLY) OPERATIONAL GUIDE When switched on, the instrument operates in the wider measurement range with a resolution of 1°. The measurement range may be changed to a higher resolution by pressing once again the ON/OFF key in HI9063 or the 0.1/1 key in HI91532K. INITIAL PREPARATION To install the batteries, turn the unit over and unscrew the battery cover. Remove the battery cover exposing the battery compartment as shown in the diagram.
HOLD MODE (HI9063 AND HI91530K ONLY) To view the input temperature of Probe 2 (T2), press the T1/T2 key and a "K2" will appear on the display. The reading hold function is activated by the HOLD key. In HI9063, the measured temperature is frozen on the display when this function key is pressed, and to resume normal operational mode, press this key again. In HI91530K, keep the HOLD key pressed to freeze the reading on the display, and to resume normal operational mode, release this key.
DISPLAY CODES GUIDE Display Description °C The instrument is reading in the Centigrade scale. HI9063, HI91530K and HI91531K only: °F The instrument is reading in the Fahrenheit scale. HI91530K, HI91531K and HI91532K only: ---- The probe is not connected to the instrument or the reading is out of range. HOLD Freezes current reading on display. BAT Batteries are weak, replace batteries. HI9063 and HI91531K only: The instrument shows the highest measured value.
HI 766PE1 General purpose probe, max 900°C/1650°F ACCESSORIES 155mm 6.1" K-TYPE THERMOCOUPLE PROBES 3mm 0.12" WITH DETACHABLE HANDLE & MINI-CONNECTOR (to be used in conjunction with the HI 766HD probe handle):: HI 766PA Roller surface probe, max 320°C/600°F HI 766PE2 General purpose probe, max 900°C/1650°F 100mm 4" 280mm 11" 7.8" 200mm 7.8" 5mm 0.20" HI 766HD Rugged thermocouple probe handle with 1m (3.3' ) cable fitted with a mini-connector HI 766PB Surface probe, max 650°C/1200°F 200mm 7.
HI 766E2 General purpose probe, max 900°C/1650°F HI 766B1 90º Surface probe, max 450°C/840°F 360mm 13.8" 220mm 8.5" 30mm 1.2" 5mm 0.2" 300mm 11.8" HI 766B2 Spring-loaded,surface probe, max 900°C/1650°F HI 766F High temperature, flexible wire probe without handle, max 1100°C/2000°F 255mm 10" 8mm 0.3" 1.5mm 0.06" 130mm 5.1" HI 766B3 Spring-loaded,small surface probe with insulated shaft, max 200°C/390°F HI 766F1 Flexible wire probe without handle, max 480°C/900°F 5mm 0.2" 2mm 0.08" 130mm 5.
WARRANTY All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The electrodes and the probes are warranted for a period of six months. This warranty is limited to repair or replacement free of charge. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument.
h t t p : / / w w w . h a n n a i n s t .