User Manual

9
alarm is triggered. For more information on the propotional band please
consult the proportional control section.
Given a conductivity alarm condition, conductivity control can be main-
tained if “Ctrl on EC alarm” is selected using panel number
S54S54
S54S54
S54 (ALARM
BEHAVIOR).
Statistical values of total conductivity are displayed on panel
C20C20
C20C20
C20 (TOTAL
AVERAGES). For the average conductivity of each irrigation program see
panel
C21C21
C21C21
C21 (PROGRAM AVERAGES) and for average conductivity of each
individual sector see panel
C22C22
C22C22
C22 (SECTOR AVERAGES).
RARA
RARA
RA
TIOMETRIC CONTROLTIOMETRIC CONTROL
TIOMETRIC CONTROLTIOMETRIC CONTROL
TIOMETRIC CONTROL
In this mode the user has to specify for each program the quantity of each
fertilizer to be dosed. The quantity can be specified in volume or in weight
of active substance. All these settings are made in panel
S41 S41
S41 S41
S41 (RATIOMETRIC
CTRL). If the volume is set Y, the proportion is dosed for each fertilizer as
volume of fertilizer solution in volume of irrigation water. If the volume is
set to N, the weight of active substance is specified together with the con-
centration of fertilizer solution. The controller will dose then the volume of
fertilizer that contains the specified active substance.
VOLUME CONTROLVOLUME CONTROL
VOLUME CONTROLVOLUME CONTROL
VOLUME CONTROL
This mode is available only if the program works with irrigation in volume.
The settings are made in panel
S42S42
S42S42
S42 (FERT VOL CTRL). Here is specified
the volume of fertilizer solution and the volume of irrigation water in which
is to be mixed.
PH CONTROLPH CONTROL
PH CONTROLPH CONTROL
PH CONTROL
pH control is necessary to correct and maintain the pH of irrigation water
within specified range: pH reference minus or plus dead band value.
The pH control also has a dead band and a proportional band. These
values are set using panel
S36S36
S36S36
S36 (pH CONTROL).
The value of pH sensor and the reference value are displayed on panel
C05C05
C05C05
C05 (pH STATE).
pH sensor value is displayed also on panel
C03C03
C03C03
C03 (SENSORS STATE) and in
C01C01
C01C01
C01 (GENERAL INFO).
pH control will generate a pH alarm if for a period of time (more than the
time specified using panel
S36S36
S36S36
S36 (PH CONTROL)) the pH is not within the
specified range. Given a pH alarm condition, pH control can be main-
tained if “Ctrl on PH alarm” is selected using panel number
S54S54
S54S54
S54 (ALARM
BEHAVIOR). Also given a pH alarm condition, irrigation can be main-
tained if “Irrig on PH alarm” is selected using panel number
S54S54
S54S54
S54 (ALARM
BEHAVIOR).