User Manual
43
EC CONTROL – S38
ECRef=07.3mS Prog 07
ECBnd: D=00.5 P=01.0
TimeOut:03min
EC CONTROL S38
The EC settings are programmed using this panel. EC control determines the
overall amount of fertilizer added to the irrigation water to maintain the de-
sired conductivity value. The Fertigation Controller controls up to 4 fertilizer
tanks relative to the EC settings established using this panel. The program
number indexes this panel. This panel displays and allows the setting of the
following parameters:
−
EC Ref - EC Ref -
EC Ref - EC Ref -
EC Ref - The selectable EC set point programmed for fertilizer dosing.
−
PP
PP
P
rogram Numberrogram Number
rogram Numberrogram Number
rogram Number - Panel index (used to view settings for all programs).
−
Dead bandDead band
Dead bandDead band
Dead band - The selectable dead band around the EC reference. The
desired (target) EC range.
−
PP
PP
P
roportional bandroportional band
roportional bandroportional band
roportional band -The selectable area around the setpoint where the
proportional control is active.
−
TimeOutTimeOut
TimeOutTimeOut
TimeOut - Selectable EC control alarm time-out (represents the time inter-
val considered from the moment when the alarm condition actually ap-
pears and the moment when the alarm will be triggered). This parameter
allows the EC control to drive the motorized valves. It sould be greater
than the time needed for the motorised valves to close/open completely.
SET FERTILIZERS – S39
Prog 07
Fer1=020% Fer2=055%
Fer3=060% Fer4=040%
SET FERTILIZERS S39
This panel sets a dosing prescription for fertilizers when fertilizer dosing is
controlled by conductivity. The Fertigation Controller can control 4 fertilizer
tanks. A percentage of each fertilizer dosed can be set using this panel. Each
tank can be set to dose from 0% to 100%. Setting each tank to dose 100%
would represent maximum dosing of all fertilizers relative to the conductivity
set point and control settings. The program number indexes this panel. This
panel displays and allows the setting of the following parameters:
−
PP
PP
P
rogram Numberrogram Number
rogram Numberrogram Number
rogram Number - Panel index (used to view settings for all programs).
−
Fert settingsFert settings
Fert settingsFert settings
Fert settings - Selectable fertilizer settings (percent) for tanks 1 through 4.