User Manual
42
−
PP
PP
P
rogram Numberrogram Number
rogram Numberrogram Number
rogram Number - Panel index (used to view settings for all programs).
−
PreIrrigPreIrrig
PreIrrigPreIrrig
PreIrrig - The selectable amount of pre-irrigation water in time or volume.
−
PP
PP
P
ostIrrigostIrrig
ostIrrigostIrrig
ostIrrig - The selectable amount of post-irrigation water in time or volume.
PH CONTROL – S36
pHRef=07.3pH Prog 01
pHBnd: D=00.5 P=01.0
TimeOut:03min
PH CONTROL S36
Typically an acid is added to reduce the pH to a desired level. The Fertigation
Controller can control 1 acid tank. A desired pH set point or target reference
is programmed and the acid dosing is controller relative to the set point. The
program number indexes this panel. This panel displays and allows the setting
of the following parameters:
−
pH RefpH Ref
pH RefpH Ref
pH Ref - The selectable pH set point programmed for pH control to main-
tain in the irrigation water.
−
PP
PP
P
rogram Numberrogram Number
rogram Numberrogram Number
rogram Number - Panel index (used to view settings for all programs).
−
Dead bandDead band
Dead bandDead band
Dead band -The selectable dead band around the pH reference. The
desired (target) pH range.
−
PP
PP
P
roportional bandroportional band
roportional bandroportional band
roportional band -The selectable area around the setpoint where the
proportional control is active.
−
TimeOut TimeOut
TimeOut TimeOut
TimeOut - Selectable pH control alarm time-out (represents the time inter-
val considered from the moment when the alarm condition actually ap-
pears and the moment when the alarm will be triggered). This parameter
allows the pH control to drive the motorized valves. It sould be greater
than the time needed for the motorised valves to close/open completely.
FERT CTRL MODE – S37
EC Ctrl: Y Prog:01
Ratiometric Ctrl:N
Vol Ctrl: N
FERT CTRL MODE S37
This panel is used to set the fertilization control mode between the three pos-
sible modes: EC control, Ratiometric control and Volume control. To select a
fertilizer control type you just have to press SET key then with the arrows keys
move the cursor to the desired type of control and pres Y key followed by
ENTER.
NONO
NONO
NO
TETE
TETE
TE
::
::
: The volume fertilizer control mode can be selected only if the irriga-
tion control mode is also in volume mode.