Instruction Manual

1312
Power Requirements
BlackStone pumps are designed to operate
to specifications within the following voltage
ranges:
100 - 130 Volts for -1 models
200 - 240 Volts for -2 models
To ensure maximum performance, check the
voltage at the point of supply to verify that it
is sufficient. It is recommended that you in-
stall a 1 Amp circuit breaker between the
pump and the power supply. This will give
additional protection to the internal circuit
and provide a convenient way to disconnect
the power supply prior to servicing the pump,
if needed.
Injection Point
Choose an injection point that allows you
to mount the injection valve assembly ver-
tically.
The spring in the injection valve assembly
(HI 721004) adds approximately 1.5 bar of
back pressure. If pumping into a high back
pressure, the spring should be removed.
Other Considerations
If you are mounting the system to a wall,
column, etc., be sure it is strong enough
to support the weight of the entire system.
The ambient temperature of the pump,
when in operation, should be between 0
and 50°C (32 to 122°F) and should be
protected from direct exposure to outdoor
elements (direct sunlight, rain, extreme tem-
peratures, high humidity, etc.).
Generally speaking, the shorter the suction
distance, the more efficient the pump oper-
ates.
INSTALLATION
Materials Needed
LDPE hose (7 meter / 22 feet) (included)
or other type of tubing (PTFE, for example)
more suitable for a specific application (op-
tional)
Optional Accessories
4 each, ceramic weights (HI 721008)
1 each, foot valve assembly (HI 721005)
1 each, injection valve assembly (HI 721004)
Location
A suitable location should:
be near to a power source
be conveniently close to the injection point
allow easy access to the flow rate control
and pipe or hose connections
be no more than 1.5 meters (5 feet) above
the operating position of the suction valve
assembly.
Dimensions for Installation
BlackStone pumps are designed for perma-
nent installation.
The pump can be mounted directly on a wall
or tank.