User's Manual

13 (0x0D)
2
30
(1) Wait time for clearing the PIR triggered (default 30
seconds) If there is no trigger during this time, it will send
Notification Notification Type is Home Security
Event is 0Parameter 1 is Motion Detection Unknown
Locationto its associated node.
(2) effective value103600 s
14 (0x0E)
1
1
When the PIR is triggeredsend basic command or not
0 Don’t send
1 Send Basic Set command
15
0x0F
1
0
When PIR is triggered , send Basic Set
0 When PIR is triggered, send 0xFF no PIR
triggered send 0x00.
1 When PIR is triggered, send 0x00 no PIR
triggered ,send 0xFF.
16(0x10)
1
1
When PIR is triggered, send Binary Sensor Report or
not (Sensor TypeMotion )
0 dont send
1 send
18(0x12)
1
2
The default unit for temperature report
1- degrees Celsius
2- Fahrenheit
19
0x13
1
1
When motion is detected, the indicator light on or off.
0 turn off
1 turn on
32
(0x20)
1
10
Low battery alarm value, Unit is percentwhen battery
power is less than this valueBattery Report 0xff
effective value10~50
172
(0xAC)
2
4 H
(240 minutes)
Interval time of automatic report of battery power,
Temperature, Humidity and Light (unit: hour)
Effective value: 0x00010x02E8(1744 hours)
(31days=31*24= 744) ;
182
(0xB6)
1
5
Threshold value to enable battery power report when the
batterys changed value exceeds the threshold set.
effective value0~50% (0x000x32)
0:this threshold value doesn’t work;
1-5: 5%
6-10: 10%etc.