User's Manual
13 (0x0D)
2
30
(1) Wait time for clearing the PIR triggered (default 30
seconds) If there is no trigger during this time, it will send
Notification (Notification Type is Home Security,
Event is 0,Parameter 1 is Motion Detection Unknown
Location)to its associated node.
(2) effective value:10~3600 s
14 (0x0E)
1
1
When the PIR is triggered,send basic command or not。
0 - Don’t send
1 - Send Basic Set command 。
15
(0x0F)
1
0
When PIR is triggered , send Basic Set:
0 - When PIR is triggered, send 0xFF; no PIR
triggered, send 0x00.
1 - When PIR is triggered, send 0x00; no PIR
triggered ,send 0xFF.
16(0x10)
1
1
When PIR is triggered, send” Binary Sensor Report” or
not (Sensor Type:Motion )。
0 – don’t send
1 – send
18(0x12)
1
2
The default unit for temperature report。
1- degrees Celsius
2- Fahrenheit
19
(0x13)
1
1
When motion is detected, the indicator light on or off.
0 – turn off
1 – turn on
32
(0x20)
1
10
Low battery alarm value, Unit is percent,when battery
power is less than this value,Battery Report 0xff
effective value:10~50
172
(0xAC)
2
4 H
(240 minutes)
Interval time of automatic report of battery power,
Temperature, Humidity and Light (unit: hour)
Effective value: 0x0001~0x02E8(1~744 hours)
(31days=31*24= 744) ;
182
(0xB6)
1
5
Threshold value to enable battery power report when the
battery’s changed value exceeds the threshold set.
effective value:0~50% (0x00~0x32);
0:this threshold value doesn’t work;
1-5: 5%,
6-10: 10%,etc.