User's Manual
Ⅷ. WAKE UP COMMAND CLASS
If the product is within the network, press and hold Z-Wave button for more than 3
seconds,it will broadcast Wake Up Notification when release the button, it will report that
the product is waked up.
Using Wake up interval set command to set the automatic wake up time. When it’s set to
0~3599,the product will keep sleeping. It will only wake up when there is a motion or
vibration or to press the button;When it’s set to 3600~7199,it will wake up for 3600
seconds; When it’s set to 7200~10799 seconds, It will wake up for 7200 seconds.
Wake Up Interval Capabilities Report CC
Default Wake Up Interval Seconds = 21600 seconds
Wake Up Interval Step Seconds = 60 seconds
Minimum Wake Up Interval Seconds = 0 seconds
Maximum Wake Up Interval Seconds = 3600x24 seconds,namely 24h
Default Wake Up Interval Seconds = 14400 seconds
Wake Up Interval Step Seconds = 3600 seconds
Default setting: 0
NOTE:
The Wake up command and sleep mode of the device are only valid when
powered by battery, but invalid when powered by USB.
Ⅸ. Advance configuration
Multisensor offers a wide variety of advanced configuration settings. Parameters below can
be accessed from main controllers configuration interface.
parameter
DEC / HEX
number
of bytes
Default Values
Description
12 (0x0C)
1
6
PIR Sensitivity configuration
0 - turn off PIR notification
1~8 - turn on PIR notification ,Corresponding to PIR
sensitivity, there are 8 levels, 1 indicates the lowest
sensitivity and 8 indicates the highest sensitivity.
!