3. Electrical Parameters
3.1 Absolute Electrical Parameters
Table 3-1 Absolute electrical parameters
Parameter
Description
Minimum
Value
Maximum
Value
Unit
Ts
Storage
temperature
–40
125
°C
VDD
Power supply
voltage
–0.3
3.6
V
Static electricity voltage
(human body model)
Tamb = 25°C
N/A
2
kV
Static electricity voltage
(machine model)
Tamb = 25°C
N/A
0.5
kV
3.2 Electrical Conditions
Table 3-2 Normal electrical conditions
Parameter
Description
Minimum
Value
Typical
Value
Maximum
Value
Unit
Ta
Working temperature
–20
N/A
85
°C
VDD
Power supply voltage
3.0
3.3
3.6
V
V
IL
I/O low-level input
–0.3
N/A
VDD x
0.25
V
V
IH
I/O high-level input
VDD x
0.75
N/A
VDD
V
V
OL
I/O low-level output
N/A
N/A
VDD x 0.1
V