User's Manual
Table Of Contents
- Chapter 1 Overview
- Chapter 2 Device Activation and Accessing
- Chapter 3 People Number Management
- Chapter 4 Temperature Measurement
- Chapter 5 Event and Alarm
- Chapter 6 Arming Schedule and Alarm Linkage
- Chapter 7 Live View
- Chapter 8 Video and Audio
- Chapter 9 Video Recording and Picture Capture
- Chapter 10 Network Settings
- 10.1 TCP/IP
- 10.3 Port
- 10.4 Port Mapping
- 10.5 Multicast
- 10.6 SNMP
- 10.7 Access to Device via Domain Name
- 10.8 Access to Device via PPPoE Dial Up Connection
- 10.9 Enable Hik-Connect Service on Camera
- 10.10 Set ISUP
- 10.11 Set Open Network Video Interface
- 10.12 Set Alarm Host
- 10.13 Set Alarm Server
- 10.14 Set Network Service
- 10.15 Set SRTP
- Chapter 11 System and Security
- 11.1 View Device Information
- 11.2 Search and Manage Log
- 11.3 Import and Export Configuration File
- 11.4 Export Diagnose Information
- 11.5 Reboot
- 11.6 Restore and Default
- 11.7 Upgrade
- 11.8 View Open Source Software License
- 11.9 Time and Date
- 11.10 Set RS-232
- 11.11 Set RS-485
- 11.12 Set Same Unit
- 11.13 Security
- 11.14 User and Account
- Chapter 12 Appendix
Thermal Presence Detector User Manual
15
6.2.4 Notify Surveillance Center
Check Notify Surveillance Center, the alarm information is uploaded to the surveillance center
when an alarm event is detected.
6.2.5 Trigger Recording
Check Trigger Recording, and the device records the video about the detected alarm event.
For recording settings, refer to Video Recording and Picture Capture
6.2.6 Set Audible Alarm Output
When the device detects targets in the detection area, audible alarm can be triggered as a
warning.
Steps
1. Go to Configuration → Event → Basic Event → Audible Alarm Output.
2. Select a Alarm Type.
3. Select Sound Type and set related parameters.
– Select Warning and its contents. Set the alarm times you need.
– Select Custom Audio. You can select a custom audio file from the drop-down list. If no file is
available, you can click Add to upload an audio file that meets the requirement. Up to three
audio files can be uploaded.
4. Optional: Click Test to play the selected audio file on the device.
5. Set arming schedule for audible alarm. See Set Arming Schedule for details.
6. Click Save.
Note