DS-PRP100
Security Radar
Diagram References
ENGLISH
Indicator
Installaon
For detailed sengs, scan the QR code to get the User Manual of Security Radar.
1. Download and install the iVMS-4200 client soware.
2. Enter Device Management page, and click Online Device.
Note: You should acvate the device for the first usage. Select the device in the Online Device List, click
Acvate, create a password to acvate the device.
Scan the QR code to get the User Manual of Security Radar.
3. Select the radar in the Online Device List. Click Add
, set the port as 80, and check Import to Group. If the
IP segment of the radar is not the same as the PC’s, click Add in the Device for Management list and enter
the radar IP address in the pop-up window to add the radar. You need to set the port as 80 and check Import
to Group.
4. Upload Map: In iVMS-4200 client soware, enter E-map, select a radar and click Add map to select a map.
5. Click Edit Scale, draw a path on the map and set the plong scale.
6. Expand the device group in the list on the le, and drag the radar onto the map.
7. Move along the edge of the required monitoring filed. Make sure the target sign (red arrow) is moving within
the radar area (gray sector) shown on the added map. If the target sign is not within the sector, you need to
adjust the mounng posion or angle of the radar.
Power on the radar and make sure there is no large object in the monitoring area. Make the detector access
into the Internet. The radar and the PC that runs the soware should be in the same IP segment.
Test the radar aer installaon to make sure it is properly mounted.
1. In iVMS-4200 client soware, select the radar on Device Management page and click to enter the
configuraon page. You can also enter the device IP address in the web browser to enter the configuraon
page.
2. Click Smart Rule Sengs - Camera Linkage Sengs.
3. Click + to add cameras to the radar.
4. Select a camera in the Camera IP Address list, and select the radar zone or the alarm line (or whole field) in
the Zone Linkage list or the Alarm Line list.
5. Add the camera to iVMS-4200 client soware: In the client soware, enter Device Management page, click
Add
in the Device for Management list, and enter the IP address, user name and password of the camera in
the pop-up window.
1. Select a reference object about 50 m away from the speed dome. On the reference object, select a point
whose altude is the same as the speed dome’s.
2. Enter the IP address of the speed dome in the web browser to enter the web client. Adjust the PTZ buons
on the Live View page to make the reference object displayed in the image, and click to zoom in the
reference object.
3. Click , and click the reference point to middle the point in the frame.
4. Enter Configuraon - PTZ - Inial Posion, and click Set to set the inial posion.
Link the camera to the Zone
Before calibraon, set the inial posion of the speed dome to ensure the tracking accuracy.
1. In iVMS-4200 client soware, enter Device Management page, click Group. Click Encoding Channels in the
group of the radar. Click Import and check cameras to link with the radar.
2. In iVMS-4200 client soware, enter E-map page, click Edit - RadarEdit - MasterSlaveEdit.
3. Click the live view window, select the linked camera needs to be calibrated, and double click the live view
window to maximum it.
4. Select Single Calibraon
as the calibraon mode.
5. Ask the calibraon staff to move in the radar detecon field. Click the track of the calibrate staff, and the
color of the selected track will change from red to white.
6. Click Add Cal to add a calibraon point.
7. Ask the calibraon staff to stand at the calibraon point within 20 to 40 m directly in front of the radar.
Note: The track disappears if the calibraon staff is standing in the place for more than 7 s. If the calibraon
staff does not move to the calibraon point when the track disappears, you need to ask the calibraon staff to
move again, and click the track of the calibraon staff to connue the calibraon.
8. Click the added calibraon point in the Info list to update the radar posion of the calibraon staff.
9. Adjust the PTZ buons on the right of the live view window to update the PTZ posion: Click +/- to scale
the calibraon staff to a fit size (The altude of the calibraon staff is about 2/3 of the altude of the window),
and adjust the PTZ to make the object align with the sign + at the center of the frame.
10. Select the live view window of the speed dome, and Check Enable Tracking.
11. Click Sure.
Calibrate the Speed Dome
Calibraon
Inial Posion sengs
Test
1
4
Wiring
3
Formang
2
5
Set Up
6
Specificaon
1. Aach the mounng bracket on the detector with four supplied screws.
2. Loosen the screws on both side of the bracket.
3. Adjust the angle of the detector.
4. Tighten the screws on both sides of the bracket to complete the installaon.
1. Aach the mounng bracket on the detector with four supplied screws.
2. Loosen the screws on both sides of the bracket.
3. Adjust the angle of the detector.
4. Tighten the screws on both sides of the bracket to complete the installaon.
a. Power Supply Indicator
Solid Green: Detector Power on
b. Fault Alarm Indicator
Flashing Red: Fault Alarm Occurred
Solid Green: Alarm Restored
c. Zone Alarm Indicator
Solid Red: Zone Alarm Occurred
Solid Green: Alarm Restored
d. Formang Indicator
Red and Green LED Flashes 3 Times: Formang
Successfully
a. Alarm Output Wiring (4-Ch Weak Current Output)
b. Alarm Input Wiring (Reserved)
c. DC Power Supply Wiring
d. Ethernet (PoE Port) Wiring
e. Grounding
Loosen the screws on the rear cover to remove the
cover. Hold the Reset buon while powering the
radar on unl the red and green LED flashes 3
mes.
Ceiling Mounng
Pole Mounng
Before You Start:
The recommended installaon height is 2.5 m.
Make sure that the mounng surface is strong enough to withstand at least 50 N, as well as four mes the
weight of the device and the bracket.
1. In iVMS-4200 client soware, enter E-map.
2. Click Edit - RadarEdit - AddZone or AddAlarmLine, and click to draw a zone or an alarm line on the radar
detecon area.
3. Right-click to finish drawing.
4. Set the parameters of the zone or alarm line in the pop-up window.
Zone: edit the zone parameters in the pop-up window. Click OK to finish the sengs.
Alarm Line: set the rule of the line (le->right, le<-right, le<->right). Click OK to finish the sengs.
Add Zone or Trigger Line for the Detector
If the speed dome is installed together with the radar, select the calibraon mode as Single Calibraon. Otherwise,
set the calibraon as Mulple Calibraon.
For single calibraon, you can refer to the following steps, and see user manual for mulple calibraon.
Note: The alarm line is not allowed to be crossed.
Before the operaon, you need to click RadarArm - AllRadarDisarm on the E-map
page or click the selected
radar and click disarm to disarm the radar.
1
1
2
2
3
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
ALL RIGHTS RESERVED.
Any and all informaon, including, among others, wordings, pictures, graphs are the properes of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries
(hereinaer referred to be “Hikvision”). This user manual (hereinaer referred to be “the Manual”) cannot be reproduced, changed, translated, or distributed, parally
or wholly, by any means, without the prior wrien permission of Hikvision. Unless otherwise spulated, Hikvision does not make any warranes, guarantees or
representaons, express or implied, regarding to the Manual.
About this Manual
This Manual is applicable to the Security Radar.
The Manual includes instrucons for using and managing the product. Pictures, charts, images and all other informaon hereinaer are for descripon and
explanaon only. The informaon contained in the Manual is subject to change, without noce, due to firmware updates or other reasons. Please find the latest
version in the company website (hp://overseas.hikvision.com/en/).
Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement and other Hikvision’s trademarks and logos are the properes of Hikvision in various jurisdicons. Other
trademarks and logos menoned below are the properes of their respecve owners.
Product Informaon
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the RE Direcve 2014/53/EU, the EMC Direcve 2014/30/EU, the LVD Direcve 2014/35/EU, the RoHS
Direcve 2011/65/EU.
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For
proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collecon
points. For more informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of as unsorted municipal waste in the European Union.
See the product documentaon for specific baery informaon. The baery is marked with this symbol, which may include leering to
indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the baery to your supplier or to a designated collecon point.
For more informaon see:www.recyclethis.info
This product operates in a European non-harmonised frequency band.
1 3
4
6
206.5 mm
228.5 mm
60.8 mm
2
a
b
c
d
NC
NO
……
……
NO COM NC
NO COM NC
b
c
d
2
4
1 2
50 m
09-29-2018 16:50:20
+
+
3D
3D
09-29-2018 16:51:22
09-29-2018 16:51:22
+
H H=h h
Initial Position
09-29-2018 16:52:07
a
b
e
1 (-24.29,42) (12,25,34)
1 (-19.79,34) (31,43,17)
a
b
Before the operaon, you need to disable the parking funcon, and set the inial posion of the speed
dome. You also need to disarm the radar.
ISED RSS Warning:
This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two
conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'ISED applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
ISED RF exposure statement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator& your body.This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Le rayonnement de la classe b repecte ISED fixaient un environnement non contrôlés.Installation et mise en œuvre de ce matériel devrait avec échangeur
distance minimale entre 20 cm ton corps.Lanceurs ou ne peuvent pas coexister cette antenne ou capteurs avec d’autres.
NO4
NC4
COM4
NO3
NC3
COM3
NO2
NC2
COM2
NO1
NC1
COM1
a
10
20
30
40
50
60
70
80
90
100
Radar
Radar
Edit Map Edit Scale RadarEdit
Edit Map Edit Scale RadarEdit
MasterSlaveEdit
Excepon detecon
Tampering alarm
Moving alarm
Power DC 12 V
Operaon temperature
–40 °C to 65 °C
Operaon humidity 10% to 90%
Dimension (W × H × D) DC 12 V
IP level
IP67
Weight 1.73 kg
Installaon
Bracket installaon
Installaon height: 1.2m to
4m
Recommended height: 2.5m
UD16651B
Model DS-PRP100
D
etecon range 100 m
H
orizontal angle 10°
Distance
m
easurement
accuracy
1.2 m
M
ax. target number 5
V
elocity range 9 to -9 m/s
A
larm line 4
Z
one 8
R
elay output
4-ch weak current output:
DC 5 VC, 0.5 A/125 AVC, 300 mW
N
etwork interface
1 RJ45 10 M/100 M
self-adapve, supports POE
C
ommunicaon prot
ocol
Standard ISAPI protocol, NAL2300
protocol, HTTP, DNS, NTP, TCP, UDP,
DHCP, ARP and SSH