User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Installation
- Chapter 3 Wiring
- Chapter 4 Device Settings
- Chapter 5 Activation
- Chapter 6 Client Software Configuration
- 6.1 Configuration Flow of Client Software
- 6.2 Device Management
- 6.3 Group Management
- 6.4 Person Management
- 6.4.1 Add Organization
- 6.4.2 Configure Basic Information
- 6.4.3 Issue a Card by Local Mode
- 6.4.4 Upload a Face Photo from Local PC
- 6.4.5 Take a Photo via Client
- 6.4.6 Collect Face via Access Control Device
- 6.4.7 Collect Fingerprint via Client
- 6.4.8 Configure Access Control Information
- 6.4.9 Customize Person Information
- 6.4.10 Configure Resident Information
- 6.4.11 Configure Additional Information
- 6.4.12 Import and Export Person Identify Information
- 6.4.13 Import Person Information
- 6.4.14 Import Person Pictures
- 6.4.15 Export Person Information
- 6.4.16 Export Person Pictures
- 6.4.17 Get Person Information from Access Control Device
- 6.4.18 Move Persons to Another Organization
- 6.4.19 Issue Cards to Persons in Batch
- 6.4.20 Report Card Loss
- 6.4.21 Set Card Issuing Parameters
- 6.5 Configure Schedule and Template
- 6.6 Set Access Group to Assign Access Authorization to Persons
- 6.7 Configure Advanced Functions
- 6.7.1 Configure Device Parameters
- 6.7.2 Configure Remaining Open/Closed
- 6.7.3 Configure Multi-Factor Authentication
- 6.7.4 Configure Custom Wiegand Rule
- 6.7.5 Configure Card Reader Authentication Mode and Schedule
- 6.7.6 Configure First Person In
- 6.7.7 Configure Anti-Passback
- 6.7.8 Configure Device Parameters
- 6.8 Configure Linkage Actions for Access Control
- 6.9 Door Control
- 6.10 Event Center
- 6.11 Time and Attendance
- 6.12 Remote Configuration via Client Software
- 6.12.1 Check Device Information
- 6.12.2 Edit Device Name
- 6.12.3 Edit Time
- 6.12.4 Set System Maintenance
- 6.12.5 Manage Network User
- 6.12.6 Manage Keyfob User
- 6.12.7 Set Security
- 6.12.8 Configure Screen Parameters
- 6.12.9 Configure Screen Parameters
- 6.12.10 Configure Advanced Network
- 6.12.11 Configure Audio File
- 6.12.12 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
- Appendix E. Communication Matrix and Device Command
Steps
Note
The
funcon should be supported by the access control device and the card reader.
1. En
ter the Access Control module.
2. On the navigaon bar on the le, enter Advanced Funcon → More Parameters .
3. Select an access control device in the device list and click M1 Card Encrypon to enter the M1
Card Encrypon page.
4. Set the switch to on to enable the M1 card encrypon
funcon.
5. Se
t the sector ID.
Note
• The sector ID ranges from 1 to 100.
•
By default, Sector 13 is encrypted. It is recommended to encrypt sector 13.
6. Click Sa
ve to save the sengs.
6.8 Congure Linkage Acons for Access Control
You can congure dierent linkage acons for the event detected by the access control device.
Aer that, linkage acons will be triggered once the event happens. This mechanism is used for
nofying the security personnel the event, or triggering automac access control in real me.
Two types of linkage acons are supported:
• Client Acons: When the event is detected, it will trigger the acons on the client, such as the
clien
t making an audible warning..
• Device Acons: When the event is detected, it will trigger the acons of a specic device, such
as buzzing of a card reader and, opening/closing of a door, ..
6.8.1 Congure Client Acons for Access Event
Even if you are far away from an access point, you can sll know what happens and how urgent the
e
vent is by conguring linked acons of access event on the client. You will be noed on the client
once an event is triggered, so that you can response to the event instantly. You can also congure
client acons of access points in a batch at a me.
Steps
Note
The linkage
acons here refer to the linkage of the client soware's own acons such as audible
warning, email linkage, etc.
1. Click E
vent Management → Access Control Event .
DS-K3G501 Series Tripod Turnsle User Manual
69