User's Manual

Table Of Contents
If enabling the funcon, user can present card on the card reader. If disabling the funcon,
the card reader for entrance cannot be used.
OK LED Polarity/Error LED Polarity/Buzzer Polarity
Set OK LED Polarity/Error LED Polarity/Buzzer LED Polarity of main board according to the
card reader parameters. Generally, adopts the default sengs.
Buzzing Time
Set the card reader buzzing me. The available me ranges from 0 to 5,999s. 0 represents
connuous buzzing.
Max. Interval When Entering PWD
When you inpung the password on the card reader, if the interval between pressing two
digits is larger than the set value, the digits you pressed before will be cleared automacally.
Tampering Detecon
Enable the an-tamper detecon for the card reader.
Communicate with Controller Every
When the access control device cannot connect with the card reader for longer than the set
me, the card reader will turn oine automacally.
Fingerprint Recognion Level
Select the ngerprint recognion level in the drop-down list.
5. Click OK.
6. Oponal: Click Cop
y to, and then select the card reader(s) to copy the parameters in the page
to the selected card reader(s).
Congure Parameters for Alarm Output
Aer adding the access control device, if the device links to alarm outputs, you can congure the
par
ameters.
Steps
1. Click Access Control → Advanced Funcon → De
vice Parameter to enter access control
parameter conguraon page.
2. In the device list on the le, click
to expand the door, select an alarm input and you can edit
the alarm input's par
ameters on the right.
3. Set the alarm output parameters.
Name
Edit the card reader name as desired.
Alarm Output Acve
Time
How long the alarm output will last aer triggered.
4. Click OK.
5. Oponal: Set the switch on the upper right corner to ON to trigger the alarm output.
DS-K3G501 Series Tripod Turnsle User Manual
58