User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Installation
- Chapter 3 Wiring
- Chapter 4 Device Settings
- Chapter 5 Activation
- Chapter 6 Client Software Configuration
- 6.1 Configuration Flow of Client Software
- 6.2 Device Management
- 6.3 Group Management
- 6.4 Person Management
- 6.4.1 Add Organization
- 6.4.2 Configure Basic Information
- 6.4.3 Issue a Card by Local Mode
- 6.4.4 Upload a Face Photo from Local PC
- 6.4.5 Take a Photo via Client
- 6.4.6 Collect Face via Access Control Device
- 6.4.7 Collect Fingerprint via Client
- 6.4.8 Configure Access Control Information
- 6.4.9 Customize Person Information
- 6.4.10 Configure Resident Information
- 6.4.11 Configure Additional Information
- 6.4.12 Import and Export Person Identify Information
- 6.4.13 Import Person Information
- 6.4.14 Import Person Pictures
- 6.4.15 Export Person Information
- 6.4.16 Export Person Pictures
- 6.4.17 Get Person Information from Access Control Device
- 6.4.18 Move Persons to Another Organization
- 6.4.19 Issue Cards to Persons in Batch
- 6.4.20 Report Card Loss
- 6.4.21 Set Card Issuing Parameters
- 6.5 Configure Schedule and Template
- 6.6 Set Access Group to Assign Access Authorization to Persons
- 6.7 Configure Advanced Functions
- 6.7.1 Configure Device Parameters
- 6.7.2 Configure Remaining Open/Closed
- 6.7.3 Configure Multi-Factor Authentication
- 6.7.4 Configure Custom Wiegand Rule
- 6.7.5 Configure Card Reader Authentication Mode and Schedule
- 6.7.6 Configure First Person In
- 6.7.7 Configure Anti-Passback
- 6.7.8 Configure Device Parameters
- 6.8 Configure Linkage Actions for Access Control
- 6.9 Door Control
- 6.10 Event Center
- 6.11 Time and Attendance
- 6.12 Remote Configuration via Client Software
- 6.12.1 Check Device Information
- 6.12.2 Edit Device Name
- 6.12.3 Edit Time
- 6.12.4 Set System Maintenance
- 6.12.5 Manage Network User
- 6.12.6 Manage Keyfob User
- 6.12.7 Set Security
- 6.12.8 Configure Screen Parameters
- 6.12.9 Configure Screen Parameters
- 6.12.10 Configure Advanced Network
- 6.12.11 Configure Audio File
- 6.12.12 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
- Appendix E. Communication Matrix and Device Command
If enabling the funcon, user can present card on the card reader. If disabling the funcon,
the card reader for entrance cannot be used.
OK LED Polarity/Error LED Polarity/Buzzer Polarity
Set OK LED Polarity/Error LED Polarity/Buzzer LED Polarity of main board according to the
card reader parameters. Generally, adopts the default sengs.
Buzzing Time
Set the card reader buzzing me. The available me ranges from 0 to 5,999s. 0 represents
connuous buzzing.
Max. Interval When Entering PWD
When you inpung the password on the card reader, if the interval between pressing two
digits is larger than the set value, the digits you pressed before will be cleared automacally.
Tampering Detecon
Enable the an-tamper detecon for the card reader.
Communicate with Controller Every
When the access control device cannot connect with the card reader for longer than the set
me, the card reader will turn oine automacally.
Fingerprint Recognion Level
Select the ngerprint recognion level in the drop-down list.
5. Click OK.
6. Oponal: Click Cop
y to, and then select the card reader(s) to copy the parameters in the page
to the selected card reader(s).
Congure Parameters for Alarm Output
Aer adding the access control device, if the device links to alarm outputs, you can congure the
par
ameters.
Steps
1. Click Access Control → Advanced Funcon → De
vice Parameter to enter access control
parameter conguraon page.
2. In the device list on the le, click
to expand the door, select an alarm input and you can edit
the alarm input's par
ameters on the right.
3. Set the alarm output parameters.
Name
Edit the card reader name as desired.
Alarm Output Acve
Time
How long the alarm output will last aer triggered.
4. Click OK.
5. Oponal: Set the switch on the upper right corner to ON to trigger the alarm output.
DS-K3G501 Series Tripod Turnsle User Manual