User's Manual

Table Of Contents
Note
The duress code, super code, and dismiss code should be dierent.
The duress code, super password, and the dismiss code should be dierent from the
authencaon password.
The length of duress code, super password, and the dismiss code is according the device,
usually it should contains 4 to 8 digits.
5. Click OK.
6. Oponal: Click Cop
y to , and then select the door(s) to copy the parameters in the page to the
selected doors(s).
Note
The door's status duraon
sengs will be copied to the selected door(s) as well.
Congure Parameters for Card Reader
Aer adding the access control device, you can congure its card reader parameters.
St
eps
1. Click Access Control → Advanced Funcon → Device Parameter .
2. In the device list on the le, click
to expand the door, select a card reader and you can edit
the c
ard reader's parameters on the right.
3. Edit the card reader basic parameters in the Basic Informaon page.
Note
The displayed parameters may vary for dierent access control devices. There are part of
par
ameters listed as follows. Refer to the user manual of the device for more details.
Name
E
dit the card reader name as desired.
Minimum Card Swiping Interval
If the interval between card swiping of the same card is less than the set value, the card
swiping is invalid. You can set it as 0 to 255.
Alarm of Max. Failed Aempts
Enable to report alarm when the card reading aempts reach the set value.
Car
d Reader Type/Card Reader Descripon
Get card reader type and descripon. They are read-only.
4. Oponal: Some of the following parameters are not listed in the Basic Informaon page, click
More to edit the parameters.
Enable Card Reader
DS-K3G501 Series Tripod Turnsle User Manual
57