User's Manual

Table Of Contents
Chapter 4 Device Sengs
You can also set the turnsle to passing mode and memory mode, pair the keyfob, inialize the
hardware, switching between RS-485 communicaon mode and RS-232 communicaon mode, and
view relay output NO/NC diagram by seng the DIP switch on the main control board.
Normal Mode: The device will work properly.
Passing Mode: There are 9 passing modes, including controlled bi-direcon, controlled entrance
and prohibited exit, controlled entrance and free exit, free bi-direcon, free entrance and
controlled exit, free entrance and prohibited exit, prohibited bi-direcon, prohibited entrance
and free exit.
Memory Mode: By default, the memory mode is enabled. When mulple cards are presented
and authencated, it allows mulple persons passing through the lane. When it counts the
passing people number is equal to the card presented mes, or no person passing through the
lane aer the last person passing, the barriers will be closed.
Note
You can also set the DIP switch on the main control board to control the entrance and exit
c
ontrolling type, keyfob pairing, etc. For details about the DIP switch value, see DIP Switch .
4.1 Pair Keyfob
(Oponal)
Pair the remote control to the device through DIP switch to open/close the barrier remotely.
Before You Start
Ask our technique supports or sales and purchase the keyfob.
Steps
1. Power o the
turnsle.
2. Set the No.4 switch of the 8-digit DIP Switch on the main control board according to the gure
below.
3. P
ower on the turnsle and it will enter the keyfob pairing mode.
4. Hold the Close buon for more than 10 seconds.
The k
eyfob's indicator of the will ash twice if the pairing is completed.
5. Set the DIP switch as OFF, and reboot the turnsle to take eect.
DS-K3G501 Series Tripod Turnsle User Manual
19