User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Installation
- Chapter 3 Wiring
- Chapter 4 Device Settings
- Chapter 5 Activation
- Chapter 6 Client Software Configuration
- 6.1 Configuration Flow of Client Software
- 6.2 Device Management
- 6.3 Group Management
- 6.4 Person Management
- 6.4.1 Add Organization
- 6.4.2 Configure Basic Information
- 6.4.3 Issue a Card by Local Mode
- 6.4.4 Upload a Face Photo from Local PC
- 6.4.5 Take a Photo via Client
- 6.4.6 Collect Face via Access Control Device
- 6.4.7 Collect Fingerprint via Client
- 6.4.8 Configure Access Control Information
- 6.4.9 Customize Person Information
- 6.4.10 Configure Resident Information
- 6.4.11 Configure Additional Information
- 6.4.12 Import and Export Person Identify Information
- 6.4.13 Import Person Information
- 6.4.14 Import Person Pictures
- 6.4.15 Export Person Information
- 6.4.16 Export Person Pictures
- 6.4.17 Get Person Information from Access Control Device
- 6.4.18 Move Persons to Another Organization
- 6.4.19 Issue Cards to Persons in Batch
- 6.4.20 Report Card Loss
- 6.4.21 Set Card Issuing Parameters
- 6.5 Configure Schedule and Template
- 6.6 Set Access Group to Assign Access Authorization to Persons
- 6.7 Configure Advanced Functions
- 6.7.1 Configure Device Parameters
- 6.7.2 Configure Remaining Open/Closed
- 6.7.3 Configure Multi-Factor Authentication
- 6.7.4 Configure Custom Wiegand Rule
- 6.7.5 Configure Card Reader Authentication Mode and Schedule
- 6.7.6 Configure First Person In
- 6.7.7 Configure Anti-Passback
- 6.7.8 Configure Device Parameters
- 6.8 Configure Linkage Actions for Access Control
- 6.9 Door Control
- 6.10 Event Center
- 6.11 Time and Attendance
- 6.12 Remote Configuration via Client Software
- 6.12.1 Check Device Information
- 6.12.2 Edit Device Name
- 6.12.3 Edit Time
- 6.12.4 Set System Maintenance
- 6.12.5 Manage Network User
- 6.12.6 Manage Keyfob User
- 6.12.7 Set Security
- 6.12.8 Configure Screen Parameters
- 6.12.9 Configure Screen Parameters
- 6.12.10 Configure Advanced Network
- 6.12.11 Configure Audio File
- 6.12.12 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
- Appendix E. Communication Matrix and Device Command
Chapter 4 Device Sengs
You can also set the turnsle to passing mode and memory mode, pair the keyfob, inialize the
hardware, switching between RS-485 communicaon mode and RS-232 communicaon mode, and
view relay output NO/NC diagram by seng the DIP switch on the main control board.
• Normal Mode: The device will work properly.
• Passing Mode: There are 9 passing modes, including controlled bi-direcon, controlled entrance
and prohibited exit, controlled entrance and free exit, free bi-direcon, free entrance and
controlled exit, free entrance and prohibited exit, prohibited bi-direcon, prohibited entrance
and free exit.
• Memory Mode: By default, the memory mode is enabled. When mulple cards are presented
and authencated, it allows mulple persons passing through the lane. When it counts the
passing people number is equal to the card presented mes, or no person passing through the
lane aer the last person passing, the barriers will be closed.
Note
You can also set the DIP switch on the main control board to control the entrance and exit
c
ontrolling type, keyfob pairing, etc. For details about the DIP switch value, see DIP Switch .
4.1 Pair Keyfob
(Oponal)
Pair the remote control to the device through DIP switch to open/close the barrier remotely.
Before You Start
Ask our technique supports or sales and purchase the keyfob.
Steps
1. Power o the
turnsle.
2. Set the No.4 switch of the 8-digit DIP Switch on the main control board according to the gure
below.
3. P
ower on the turnsle and it will enter the keyfob pairing mode.
4. Hold the Close buon for more than 10 seconds.
The k
eyfob's indicator of the will ash twice if the pairing is completed.
5. Set the DIP switch as OFF, and reboot the turnsle to take eect.
DS-K3G501 Series Tripod Turnsle User Manual