Quick Start Guide
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Wiring
- 2.1 Components Introduction
- 2.2 Wiring Electric Supply
- 2.3 Wire Interconnecting Cable
- 2.4 Terminal Description
- 2.4.1 Master Control Board Terminal Description
- 2.4.2 Slave Control Board Terminal Description
- 2.4.3 Main Control Board Terminal Description
- 2.4.4 Main Control Board Serial Port ID Description
- 2.4.5 RS-485 Wiring
- 2.4.6 RS-232 Wiring
- 2.4.7 Wiegand Wiring
- 2.4.8 Barrier Control Wiring
- 2.4.9 Alarm Output Wiring
- 2.4.10 Fire Alarm Module Wiring
- Chapter 3 Installation
- Chapter 4 Device Settings
- Chapter 5 Activation
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
- Appendix E. Error Code Description
- Appendix F. Communication Matrix and Device Command
Figure 2-6 Main Control Board
Acc
ording to the picture above, the RS-485 serial port corresponds to UART2 and UART3. RS-232
serial port is corresponded to UART7 and UART8. Wiring Interface is corresponded to UART1,
UART4, UART6, UART6, and Lane.
The main control board descripons are as follows:
UART2/UART3 Jumper Cap
Reserved serial port. Use the jumper cap to switch the serial port communicaon mode. You
can switch between the RS-485
communicaon mode and the RS-232 communicaon mode. By
default, it is in RS-485 communicaon mode.
UART6 Jumper Cap
Use the jumper cap to switch the serial port communicaon mode with the slave lane
c
ontroller. You can switch between the RS-232 communicaon mode and the RS-485
communicaon mode. By default, it is in RS-232 communicaon mode.
UART5 Jumper Cap
Use the jumper cap to switch the serial port communicaon mode with the slave lane
c
ontroller. You can switch between the RS-484 communicaon mode and the RS-232
communicaon mode. By default, it is in RS-485 communicaon mode.
UART1 Jumper Cap
Use the jumper cap to switch the serial port communicaon mode with the master lane
c
ontroller. You can switch between the RS-484 communicaon mode and the RS-232
communicaon mode. By default, it is in RS-485 communicaon mode.
Lane
Use the jumper cap to switch the serial port communicaon mode with the lane controller. By
default, the interface is wired and it is in RS-485 communicaon mode. If wiring other
controllers (compable with Hikvision communicaon protocol), use the jumper cap to switch
between RS-485 and RS-232 communicaon mode.
DS-K3B501S Series Swing Barrier Quick Start Guide
12