Quick Start Guide

Figure 2-4 Wire General Device
Note
The supplied interconnecng cable length is 3.75 m. If you need a longer one, ask our technique
supports or sales and pur
chase for 5.5 m interconnecng cables.
The suggested inner diameter of the low voltage conduit is larger than 30 mm.
If you want to bury both of the AC power cord and the low voltage cable at the entrance, the
two cables should be in separated conduits to avoid interference.
If more peripherals are required to connect, you should increase the conduit diameter or bury
another conduit for the external cables.
The external AC power cord should be double-insulated.
The suggested network cable should be CAT5e or the network cable has beer performance.
And the sug
gested network cable length should be less than 100 m.
2.3.2 Wire Face Recognion Terminal
The picture displayed below describes the interconnecng cable's wiring diagram.