Quick Start Guide
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Wiring
- 2.1 Components Introduction
- 2.2 Wiring Electric Supply
- 2.3 Wire Interconnecting Cable
- 2.4 Terminal Description
- 2.4.1 Master Control Board Terminal Description
- 2.4.2 Slave Control Board Terminal Description
- 2.4.3 Main Control Board Terminal Description
- 2.4.4 Main Control Board Serial Port ID Description
- 2.4.5 RS-485 Wiring
- 2.4.6 RS-232 Wiring
- 2.4.7 Wiegand Wiring
- 2.4.8 Barrier Control Wiring
- 2.4.9 Alarm Output Wiring
- 2.4.10 Fire Alarm Module Wiring
- Chapter 3 Installation
- Chapter 4 Device Settings
- Chapter 5 Activation
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
- Appendix E. Error Code Description
- Appendix F. Communication Matrix and Device Command
Figure 2-4 Wire General Device
Note
• The supplied interconnecng cable length is 3.75 m. If you need a longer one, ask our technique
supports or sales and pur
chase for 5.5 m interconnecng cables.
• The suggested inner diameter of the low voltage conduit is larger than 30 mm.
• If you want to bury both of the AC power cord and the low voltage cable at the entrance, the
two cables should be in separated conduits to avoid interference.
• If more peripherals are required to connect, you should increase the conduit diameter or bury
another conduit for the external cables.
• The external AC power cord should be double-insulated.
• The suggested network cable should be CAT5e or the network cable has beer performance.
And the sug
gested network cable length should be less than 100 m.
2.3.2 Wire Face Recognion Terminal
The picture displayed below describes the interconnecng cable's wiring diagram.
DS-K3B501S Series Swing Barrier Quick Start Guide
6