User's Manual

AX PRO User Manual
27
2. Tap a zone in the Device tab.
3. Tap .
4. Tap Edit Icon the zone name.
5. Select a zone type.
Instant Zone
This Zone type will immediately trigger an alarm event when armed.
Delayed Zone
Exit Delay: Exit Delay provides you time to leave through the defense area without alarm.
Entry Delay: Entry Delay provides you time to enter the defense area to disarm the system
without alarm.
The system gives Entry/Exit delay time when it is armed or reentered. It is usually used in
entrance/exit route (e.g. front door/main entrance), which is a key route to arm/disarm via
operating keyboard for users.
Note
You can set 2 different time durations in System Options Schedule & Timer.
Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1.
If the zone is a delayed zone, you can set Enter delay/Exit delay parameters.
Follow Zone
The zone acts as delayed zone when it detects triggering event during system Entry Delay,
while it acts as instant zone otherwise.
Perimeter Zone
The system will immediately alarm when it detects a triggering event after the system is
armed. There is a configurable interval timer between the alarm activation and sounder
output "Sounder Delay Time (Perimeter Alarm) 0 to 600 Seconds". This option allows you to
check the alarm and cancel the sounder output during the interval time in case of false alarm.
When the zone is armed, you can set the peripheral alarm delayed time in System Options
Schedule & Timer. You can also mute the sounder in the delayed time.
24h Silent Panic Zone
This zone type is active 24hrs, it is used for Panic or HUD (Hold Up Devices) not smoke
sensors or break glass detectors.
Panic Zone
The zone activates all the time. It is usually used in the sites equipped with panic button,
smoke detector and glass-break detector.
Fire Zone
The zone activates all the time with sound/sounder output when alarm occurs. It is usually
used in fire hazardous areas equipped with smoke detectors and temperature sensors.
Gas Zone