User's Manual

AX PRO User Manual
26
4. Select the Protocol Type as ADM-CID, ISUP, SIA-DCS, *SIA-DCS, or *ADM-CID to set uploading
mode.
ADM-CID or SIA-DCSYou should select the Alarm Receiver Type as IP or Domain name, and
enter the IP/domain name, port number, account code, timeout, re-upload times and
heartbeat interval.
Note
Set the heartbeat interval with the range from 10 to 3888000 seconds.
ISUPYou do not need to set the ISUP protocol parameters.
*SIA-DCS or *ADM-CIDYou should select the Alarm Receiver Type as IP or Domain name,
and enter the IP/domain name, port number, account code, retry timeout period , attempts,
heartbeat interval, encryption arithmetic, password length and secret key.
Note
Set the heartbeat interval with the range from 10 to 3888000 seconds.
For encryption arithmetic: The panel support encryption format for information security
according to DC-09, AES-128, AES-192 and AES-256 are supported when you configure the
alarm center.
For the secret key: When you use an encrypted format of DC-09, a key should be set when
you configure the ARC. The key would be issued offline by ARC , which would be used to
encrypt the message for substitution security.
Device Maintenance
You can reboot the device.
Steps
1. In the site, tap the AX PRO and then log in to the device (if required).
2. Tap Project Maintenance Device Maintenance to enter the page.
3. Tap Test, and tap Start Walk Test to test the whether the device works properly or not.
3. Tap Maintenance Reboot Device .
The AX PRO will reboot.
Device Management
Enter a short description of your concept here (optional).
This is the start of your concept.
Zone
You can set the zone parameters on the zone page.
Steps
1. In the site, tap the AX PRO and then log in to the device (if required).