Use and Care Manual
ENGLISH
10
HELPFUL TIPS
POSSIBLE CAUSE SOLUTION
The POWER is o Turn on by pressing the POWER button
No input voltage Check whether the DC connection of Handy
Power X is loose or damaged
The DC fuse has broken Check that the user has installed and
complies with standard fuses
Please check and replace the internal fuse by
qualied maintenance technician
AC circuit breaker has tripped Disconnect all appliances to reduce the overload, then
turn it o to reset the device and back to on again.
LCD display screen shows
OVP fault code
Overvoltage Protection started,
Check the battery voltage whether within the working
voltage range, and the output can be restored
LCD display screen shows
UVP fault code
Low-voltage Protection started,
Check the battery voltage whether within the working
voltage range, and the output can be restored
LCD display screen shows
OTP fault code
Overtemperature Protection started,
Check whether the fan turns, and the output can be
resumed after the temperature drops
LCD display screen shows
OLP fault code
Overload Protection started,
Check whether the load exceeds the rated power, and
the output can be resumed after reducing the power
LCD dispaly screen shows
SCP fault code
Output Short Circuit Protection started,
Check whether there is short circuit in the load, and the
output can be resumed after the short circuit is removed
Internal temperature has not
reached the fan's start value
No action. The fan will turns on automatically when the
internal temperature reachs the fan's start value
Fan is damaged Please check and replace the internal fan by qualied
maintenance technician