Brezina Installation Manual
24" 24" 24"
24"
STAMP ID WOOD COMPONENTS
AC PLYWOOD CENTER X 4
BAG # HARDWARE
1701PC #8 X 1-1/2" WOOD SCREW X 24
STEP 22: PLYWOOD
INSTALL AC FIRST. WITH STAMP ID UP. X4 (FIG. 22.1)•
USE ONE #8 X 1-1/2" WOOD SCREW AT EACH CORNER OF PLYWOOD AS SHOWN. (FIG. 22.2)•
BOTTOM EDGE OF PLYWOOD MUST BE FLUSH TO FASCIA AS SHOWN. (FIG. 22.3)•
CENTER AND SNAP CHALK LINES OVER ROOF DECKING.•
CHALK LINES
UP
STAMP ID
FIG. 22.1
PLYWOOD
FLUSH TO FASCIA
BOTTOM OF PLYWOOD
FASCIA
#8 x 1-1/2" Wood Screw
FIG. 22.3
FIG. 22.2
SEAM
AC
49