Minimum signal for association: Set the minimum signal value (SNR) for client can associate to
this WLAN. The range is 0~100dB, and 0 means disable.
Disconnect Signal ThresholdSet the signal threshold value (SNR) for client to disconnect to this
WLAN.
Disconnect Packet ThresholdSet the packet threshold value (SNR) for client to disconnect to this
WLAN.
Back to WLAN ListGo back to previous page
Procedures
1. Select Configuration -> Wireless -> Radio0 (2.4G) -> WLAN to click “More…” behind
the WLAN, and then select WLAN General.
2. Enable WLAN select to enable this WLAN
3. VLAN Pass Through allow or don’t allow VLAN pass through
4. VLAN TagId Set VLAN ID
5. SSID set SSID
6. Allow Intra-WLAN User Isolation: Allow or block intra-WLAN User communication.
7. Max Clients Maximum is 64
8. Click Submit
9. Click Save&Apply to apply
2. WLAN X (0-7) Security
AP-100 2.4GHz supports Open, Shared Key, WPA, WPA-PSK, WPA2, WPA2-PSK, WAPI,
WAPI-PSK authentication mode, and Disabled, WEP, AES, TKIP, SMS4 cipher mode.
Select Configuration -> Wireless -> Radio0 (2.4G)-> WLAN to edit “More…” WLAN, and then
select WLAN Security to access to security configuration page.