B–4 Technical Specifications
Indicators: Beeper.
See descriptions below.
Beeper
The good read/no read beeper indicator is configurable and can be disabled, if desired.
B.4 Environmental Specifications
Operating Temperature: 32° F to 122° F (0° C to +50° C)
Storage Temperature: –40° F to 158° F (–40° C to +70° C)
Relative Operating
and Storage Humidity: 0 to 95% (non–condensing)
Barometric Pressure: 101,000 to 69,000 Pascals
(Sea level to 3000 meters)
ESD: 15 KV
A drain path for ESD should be provided when installing a 3700 in the host system.
Shock (Drop Test): Sustains three (3) drops from 4 feet (1.2
meters) to a non–yielding surface
Mean Time Between
Failure (Ground Benign): 45,000 hrs. minimum
(will vary among models)
B.5 Mechanical Specifications
3700: Width: 3.5 Inches (89mm)
Length: 2.9 Inches (75mm)
Height: 1.05 Inches (26m)
Interface Cables: 1) Welch Allyn p/n 42204595–01
Input/Output cable with 25 pin connector.
Note: A null modem is required for connection to a DTE type port.
Mounting Holes: Four #6–32 UNC–2B (M3.5)