User manual
4–14 Configuring the SCANTEAM 3700
Set Code 128 Command Kt
COMMAND
<Kt enable, minimum length, maximum length>
Parameter ASCII Option
Enable 0 no
1 yes *
Minimum Length Set from 1 to 80 * (1)
Maximum Length Set from 1 to 80 * (80)
Sending the configuration command Kt sets Code 128 and all its parameters:
enable/disable, minimum length, and maximum length. The default setting is Code 128
enabled, minimum length 1, and maximum length 80.
Set Beeper Mode Command Ku
COMMAND
<Ku mode_global, mode_port_1, mode_port_2, #>
Parameter
ASCII Option
Mode 0 Disable beeper *
Mode 1 Enable beeper on valid read
Mode 2 Enable beeper on failed read
Sending the configuration command Ku sets the beeper mode. For example, if you
wanted to enable the beeper for good reads on port 1; you would send the following
command: <Ku , 1>. The default setting is Mode_global 0, with beeper disabled.
Set Scan Rate Command Kv
COMMAND
<Kv rate, reserved, reserved>
Parameter
ASCII Option
Rate 0 50 scans per second
Rate 1 100 scans per second
Rate 3 200 scans per second
The Kv command has been retained in the 3700 for compatibility with the SCANTEAM
3600, but the 3700 scan rate is fixed at the time of manufacture and cannot be changed
by the Kv command. The <Kv?> status request (see next section) will report the scan
rate setting.