Installation Instructions

Cutout Template
IC5020 and IC5220: EXTERNAL ANTENNA
6
10
3/8”
17
5/8”
19
3/4”
1 - 9/16”
40
86
3 - 3/8”
35
1 - 3/8”
1/8”
254
10”
33
1 - 5/16”
17
IC5020: 11/16”
Reader/Antenna Hybrid Electric Strike
4
R- 5/32”
21
IC5220: 13/16”
3
IC5020 and IC5220: EXTERNAL ANTENNA
Installation Directions
1. Prepare door jamb for hybrid electric strike per the appropriate
template detail (see pages 4-6). Be sure to allow enough room
behind the strike in the cutout to avoid pinching any wires.
2. Drill a 1” diameter hole for reader/antenna per the appropriate
template detail (see pages 4-6). Note that the reader/antenna may
be positioned as desired, within limits of the 24”cable. If necessary,
drill a channel from the reader/antenna to the hybrid electric strike
to accomodate the 24“ cable.
3. Drill a 3/8” hole for the door position switch per the appropriate
template detail (see pages 4-6). Note that the door position switch
may be positioned as desired, within limits of its 10” connector. If
necessary, drill a channel from the door position switch to hybrid
electric strike to accomodate the 10“ cable. Next, drill a matching
3/8” hole in the door and install the press-fit magnet so that it will
contact with the door position switch.
4. If applicable (e.g. aluminum frames), install mounting tabs (sold
separately as P/N 152) using #10-32 screws.
5. Verify that the strike is in the correct mode of operation. This
unit ships in fail secure mode. If you need to convert to fail safe, see
page 7.
10. Plug the loose end of the 24” cable into the connector on the
side of the hybrid electric strike.
Prepare Frame
11. Attach the faceplate to the hybrid electric strike, using the
#8-32 screws provided.
12. Install the trim enhancer on the hybrid electric strike (if
needed to cover any extra space).
13. Install the hybrid electric strike unit in jamb cutout, using
#12-24 screws provided.
14. If needed, see page 8 to make horizontal adjustments in
frame (IC5220 only).
15. If applicable, tighten the #10-32 screws holding the
mounting tabs.
Finish Installing
16. When power is supplied to the hybrid electric strike, the LED
will flash green three times, while the beeper simultaneously
beeps. The LED will then turn red. This sequence indicates that the
micro-controller is operating properly.
17. Present a Proximity ID card to the reader/antenna. The LED will
turn green, while the beeper beeps once. This indicates that the
card was read successfully.
18. Simultaneously, the keeper will click open. This indicates that
communication between the host and the hybrid electric strike is
operational.
19. For further testing of communication with the host, consult the
manual for the control panel or the site’s system administrator.
Testing and Operation
Connect Components and Wiring
Wire Gauge Diagram
Max. One-way Distance Voltage Drop/100’ Recommended AWG
800’
500’
300’
200’
120’
100’ or less
12VDC @ 240 mA
0.15
0.24
0.38
0.61
0.97
1.53
12 Gauge
14 Gauge
16 Gauge
18 Gauge
20 Gauge
22 Gauge
3
Remove additional material as
needed to provide clearance for
hybrid electric strike and wires
6. Check that the wires running from the host control panel are
adequate wire gauge for the components and distance (see Wire
Gauge Diagram below). Connect the wire leads of the three pigtails
provided to the host control panel wiring based on the wiring
diagram on page 2 and the appropriate termination at the host
control panel.
7. Mount the door position switch (DPS) into the frame. Route the
10” cable back to the electric strike and connect it to the 2 pin
connector coming out of the hybrid electric strike. It does not
matter which 2 pin connector is used. Note: the LBM & DPS are
wired in series--a ‘closed’ electrical circuit depicts a closed door
and extended latchbolt into the hybrid electric strike.
8. Attach the 8, 4 and 2 pin connectors at the hybrid electric strike
to the equivalent pigtail connectors routed from the host control
panel. Apply grease to the pigtail electrical terminals if used in a
humid environment
CAUTION! Before connecting any device at the installation site, verify input voltage using a multimeter. Many power supplies
and low voltage transformers operate at higher levels than listed. Any input voltage outside the electrical specifications
outlined on page 1 may cause severe damage to the unit and will void the warranty. This product contains electrostatic sensitive
components. We recommend proper grounding techniques be observed during installation.
IC5020 or IC5220 with 504 Faceplate
1-3/8” x 10” Radius Corner Faceplate
Aluminum Jamb Installations
9. Secure the Reader/Antenna Mounting Plate to the frame
using the #6-32 screws provided. Connect the 24” cable to
the Reader/Antenna, snap the Reader/Antenna to the
Reader/Antenna Mounting Plate and pull the 24” cable
through to the hybrid electric strike.