Installation Instructions

Hybrid Electric Strike
Reader/Antenna Body
#6-32 Reader/Antenna Screws
Reader/Antenna Mounting Plate
24” Cable (connecting reader/antenna and strike)
Door Position Switch, Press-Fit Magnet
and 10” Connector Cable (2 pin)
Product Components
Pigtail Connectors
2 pin-DPS & LBM
4 pin-12V Strike Power
4 pin-24V Strike Power
Faceplate (sold seperately)
#12-24 Mounting Screws (included with faceplate)
#8-32 Faceplate Screws (included with faceplate)
Prox & Data Connector (connects to strike)
Prox & Data Pigtail
Dielectric Grease (for humid applications)
IC5020 and IC5220: EXTERNAL ANTENNA
1
2
3
4
5
6
7
8
9
11
10
12
13
Access Control System
Control Panel and Power Supply
(By others)
8 Pin Connector (Reader Module)
Red (+) Board Power
Black ( ) Board Power
Green Data 0
White Data 1
Yellow LED/Buzzer
Blue Not Used
Orange Not Used
Brown Not Used
2 Pin Connector (Door Position Switch)
Wire plugs into Hybrid Electric Strike
Wiring Diagram
2
Fail Safe Conversion
IC5020 and IC5220: EXTERNAL ANTENNA
7
-
2 pin Connector (Strike Module)
Tan Common
Pink Door Closed and Latch Engaged
Dielectric
Grease
a. In order to change the mode of operation from fail secure
(standard) to fail safe, first detach the reader module by removing
the two screws on the back of the hybrid electric strike.
Remove Reader Module
b. Loosen the two #2-56 screws located on the back of the
strike module, as shown above, but do not remove them.
c. Move screws from the top of the hole to fail safe position.
d. Tighten screws.
Convert Mode
e. Replace the reader module and tighten the two
screws to hold it in place.
Finish
c
Fail Safe
-or-
1
2
3
5
6
7
8
9
10
12
11
14
15
4
13
a
Trim Enhancer
14
Trim Enhancer Screws
15
4 Pin Connector (12V Strike Power)
Red (+) Strike Power
Black (−) Strike Power
4 Pin Connector (24V Strike Power)
Violet (+) Strike Power
Black
(−) Strike Power