Installation and Operating Instructions

Page 2 of 14
For more information visit website assaabloyesh.com P/N: 3080006.017_1
Recommended tools
Cutting Wheel
Phillips #2 Screwdriver
Hardware Specifications
Table 1 Cam
DPS Cable Extension
Optional The DPS signal is closed when the handle is resting in its locked position. The DPS circuit can be
extended to include normally open DPS switches arranged in a series to monitor additional doors and panels
CAM
CAM LENGTH
CAM
DEPTH
38mm - 4
(Standard)
38mm [1-1/2"]
26mm [1”]
38mm - 5
(Optional)
38mm [1-1/2”]
28mm
[1-1/10"]
45 mm - 1
(Optional)
45mm
[1-3/4”]
18mm
[7/10”]
For Technical Support Please call 1-800-810-WIRE
DPS Extension Cable
Switches
(SPST-NO):
As Needed
Optional
Switch #1
(SPST-NO):
Provided
Extending the DPS Circuit:
A: Remove the DPS jumper
B: Connect the included DPS extension
cable
C: Connect additional normally open
DPS switches as shown to monitor
additional panels.