DRAFT
3. Wiring the Hub.
The Aperio Hub connects to the Access Control system via Wiegand wiring. The hub requires 8-24VDC power
(250mA). The hub includes two form C relays that can be used to transmit door position and tamper detection
signals. The hub connects to the cabinet lock wirelessly.
4. Installing an SFIC Core
A key override (SFIC) provides a backup entry method in the rare case the KS100 or access control system is
inactive. We recommend this option.
The included SFIC cam has been tested with Medeco and Sargent 6- or 7-pin SFIC cores.
*Note: the Green LED input is used to grant access to the
cabinet lock. If the Green LED signal is not available to
indicate approved access, the approval input can be activated
by a relay with NO attached to Green LED and COMMON to
GND.
*Note: the Red LED input is used to indicate access denied.
If the RED LED signal is not connected, the lock will flash RED
3 times when a non-approved card is presented indicating loss
of connection to the hub rather than access denied. Refer to
the LED reference card for any other codes.
*Note: the DPS signal will trigger when
either the latch handle or the door is out
of position. Both the latch handle and
door must be in position for a secure DPS
signal.