User Guide
3
Air pressure regulator button
Air pressure gauge
Water filter
Water outlet
Oil way
Oil atomizer
Fig. 1 Air supply treatment diad
4⸠1.3
Air Pressure Regulation
Refer to pressure regulation way as below:
(See Fig. 1 Air supply treatment diad) Pull up the pressure regulator button of
air supply treatment device. Turn it slowly and observe the pressure gauge
finger. Press the button down when the finger points to the required air
pressure value. The air pressure shall be regulated accurately. If the air
pressure is lower than 0.4 Mp, the pneumatic system can not go on work
normally. If the air pressure is over high, it is possible that shock will occur
and corresponding parts will be damaged earlier.
4⸠1.4
Check the position
of rotary disk valve
The core of rotary disk valve (Fig. 3-11) has been adjusted in the factory. But
fortuitous event will also cause error position of valve core. Check whether
the valve core hole aligns with the valve body hole as shown in Fig 2 rotary
disk before use. When adjusting to suction position, the rotary disk valve
cylinder (Fig. 3 -15) shall be in minimal position (close position). When
adjusting to discharge position, it shall be in maximal position (open
position).
4⸠1.5
Connect to the hopper
See Fig. 3 Whole Machine Parts. Generally, the hopper (Fig. 3-16) is fixed to
the upper port of the rotary disk valve firmly. You can also choose stainless
steel tube adapter for pipe connection.
If it is necessary to heat, pressurize or mix for filling of material in large
viscosity and poor fluidity, heating, pressurizing or mixing hoppers are
available for option. If the user refits the hoppers or other fittings with
permission or use them from other factory, the manufacturer will take no
responsibility. Such risks will be undertaken by the user solely.
3
A
A
Suction Position Discharge Position
Connect to discharge nozzle
Connect to hopper
Connect to cartridge
Fig. 2 Rotary Disk Valve