User Guide
During maintenance, you must comply with the maintenance precautions
strictly, otherwise the safety operation of the machine can not be guaranteed.
Maintenance
2⸠4
2
Technical Parameters
3.
The following table takes standard single head horizontal filler for example:ointment
GFA-150
GFA-300
Filling volume (ml)
Production capacity (cycle/min)
Applicable pressure(Mpa)
Type
Filling accuracy (FS)
Applicable tolerance (m³/min)
Exterior sizes (mm)
Net weight (kg)
GFA-500 GFA-1000
10-150 20-300 20-500 30-1000
±0.5%
±0.5%
±0.5%
±0.5%
1-25
1-25
1-25
1-25
≥0.1 ≥0.1 ≥0.1 ≥0.1
0.4-0.9 0.4-0.9 0.4-0.9 0.4-0.9
900×280×650
1000×280×650
40 40 40 45
4.
Operation guidelines
Preparation
for Startup
4⸠1
This machine uses three-strand power plug, so you should check new power
socket to ensure its reliable grounding.
This machine shall be used with air compressor, of which, the air displacement shall be
not less than 0.1m³/min and the applicable air pressure is able to adjust from 0.4 to 0.9
Mpa.
Before startup, clean all the parts which come into contact with the materials.
The application of universal snaps and yokes in international type facilitates
the loading and unloading.
Check whether the oil cup (oil feeder) of oil atomizer is filled with sufficient
oil. The oil atomizer shall be filled with 2.5 -7ºE lubricant (20# or 30# turbine
oil). Oiling and volume regulation ways are listed as below:
Before cutting off the gas source, push upward or transverse by hand the water
outlet at the bottom of filler to discharge the remaining gas. Screw out the
screw plug on the oil way in the center above the oil atomizer. Then oil may be
injected through this hole. A vent hole, which is close to this oil way, may be
opened if it is difficult in oiling. The oil level shall be between the min. and
max. oil scale. Screw down each screw plug after oiling. A volume regulator
inside above the filter can be used to adjust the volume of lubricant after
entering post pneumatic components. Generally, turn on the regulator in 1 to 2
turnings in close condition.
4⸠1.1
Cleaning
4⸠1.2
Oiling of Oil Atomizer
900×280×650 900×280×650
2