Instruction Manual
EN
12
MAINTENANCE
• Remove the batteries when the product is
not in use.
• Wipe the spout clean of contaminants
and debris every week.
3. Immerse the suction pipe’s inlet (1) below
the surface of the liquid in the tank from
which pumping is to take place, then
insert the outlet hose (2) down into the
tank (3) that is to be lled.
FIG. 4
4. Press the power switch. Turn o the pump
with the power switch before the tank is
overlled.
WARNING!
The product must not be used for liquids
hotter than 60°C.
IMPORTANT:
• Do not allow the product to run dry.
Do not start the product until the suction
tube’s inlet is below the surface of the
liquid.
• Do not use the product for thinner or
solvents.
• Do not use the product for hot water.
• Do not use the product for strong
solvents or corrosive chemicals, such as
acetone, benzene, cresol, ethanol,
phenol, 1-methylethyl, concentrated
sodium hydroxide, nitric acid,
hydrochloric acid, sulphuric acid.
• Do not run the product upside-down
after use.
• Remove the batteries when the product
is not in use.
• Only use the product in a cool and well
ventilated environment.
LOW LIQUID FLOW
A low liquid ow may be due to the batteries
being discharged, in which case you should
change the batteries, or to the liquid level
in the storage tank being too low. Top up if
necessary.