Installation Guide
Figure 14
Outlet box
Mounting
bracket
Canopy
Screw
Screw
Step 1. Tuck connections neatly into ceiling
outlet box.
Step 2. Remove one screw from the mounting
bracket and loosen the other screw
approximately 1/4.
Step 3. Align the canopy up to ceiling and over
the loosened screw. Place the canopy into key
hole and rotate canopy clockwise. (Figure
14)
Step 4. Secure the canopy by using
previous removed and loosened screws.
Step 5. Place the canopy cover to the
can o p y a n d r o tat e can o p y c o v er
clockwise until it is locked into right
position.(Figure 14)
SUPPLY CIRCUIT
Ground
Conductor
Outlet Box
Green
Ground
Lead
Ground to
Downrod
BLACK
WHITE
WHITE
WHITE
WHITE
BLACK
BLACK
BLACK
BLUE
BLUE
GREEN
Figure 13
ON
Canopy Cover
WARNING
MAKE SURE TAB AT BOTTOM OF HANGER
BRACKET IS HANGER PROPERLY SEATED IN
GROOVE OF HANGER BALL BEFORE
ATTACHING CANOPY TO BRACKET. FAILURE TO
PROPERLY SEAT TAB IN GROOVE COULD CAUSE
DAMAGE TO ELECTRICAL WIRING.
6
Finishing the Installation