Installation Guide

If the glass contacts the blade, please follow the steps below:
1. Cut the adaptor connector of the wires from the tter.
2. Thread the wires from the tter through nut, spacer nut, threaded pipe and sleeve.
3. Insert the black and white wires from the light kit through the center hole of the switch box; thread the switch box
onto the light kit. Re-install lock washer and hex nut and tighten securely. Connect the black wire from the tter to
the extra black wire provided. Connect the white wire from the tter to the extra white wire provided. Use the wire
nuts to make the connection. Make sure all the wire laments are inside the wire nuts.
4. Connect the adaptor connectors from all extra wires provided to the adaptor connectors from the switch cup.
Go to step 5 to nish the installation.
CAUTION: All glass is fragile, use care when handling glass shade and lamp.
CAUTION: Allow the bulb and glass shade to cool completely before touching or replacing to avoid accidental burning
of the skin.
CAUTION: To reduce the risk of re and electric shock, this light kit should be used only with the following fan
models 56-ATR (SKU# 834-492, 672-000, 672-066, 671-934), 68-ATR (SKU# 904-384, 129-954). Manufactured by
Chienluen Industries (Zhongshan) Ltd.
Weight of the light kit: 1.42 KGS
UL Model No: LK-ATR