Use and Care Guide

10
Troubleshooting Guide
Control panel does not illuminate.
Unit is not connected to an electrical outlet. Plug into outlet.
Circuit breaker is tripped. Reset circuit breaker.
Unit is on but is not functioning once the lid is closed.
Lid microswitch needs to be adjusted. Contact Technical Services.
Pump is damaged. Contact Technical Services.
Lid does not open automatically.
Gas spring is damaged. Contact Technical Services.
Display shows “F.1.”
Lid microswitch needs adjusting. Contact Technical Services.
Pump requires maintenance. Contact Technical Services.
Display shows “--.”
Lid does not open correctly. Inspect lid.
Display shows “CO.”
Unit needs a scheduled oil change. Contact Technical Services.
Final vacuum is insufficient.
Set vacuum time is too short. Extend vacuum time.
There is not enough oil in the vacuum pump. Add oil or change oil.
Extraction hole in back of chamber is partially covered by vacuum pouch during extraction. Place pouch
closer to the sealing bar.
Lid gasket is worn down. Replace lid gasket.
Oil is contaminated. Change oil.
Oil exhaust filter is wet. Contact Technical Services.
Unit extracts air too slowly.
Oil exhaust filter is wet. Contact Technical Services.
Vacuum pump’s extraction filter is blocked. Contact Technical Services.
Vacuum pouch is sealed improperly.
Vacuum pouch is being placed on sealing bar incorrectly. Place pouch neatly on the sealing bar ensuring
that the opening of the pouch is inside the chamber.
Sealing time is either too short or too long. Adjust sealing time accordingly.
Sealing pad beneath lid is worn or damaged. Replace seal pad.
Sealing wire needs replacement. Replace sealing wire.
Vacuum pouch opening is soiled. Clean pouch opening.