Manual

3
Note - Power Delivery / QC 3.0, 2.0
Plug & GO: no additional software required,
simply plug in and start:
Thanks to Power Delivery / QC 3.0, 2.0, the
voltage and power are adjusted automatically.
Be aware that, for ecient and optimised
charging, your terminal device must support the
PD (Power Delivery) / QC 3.0, 2.0 function.
If you have a large number of PD/QC-enabled
devices with different rmware updates, it may
be that the function is not fully supported.
Warning
Only operate the product from a socket that has
been approved for the device. The socket must
be installed close to the product and must be
easily accessible.
Disconnect the product from the power supply
using the On/Off switch if this is not available,
unplug the power cord from the socket.
If using a multi-socket power strip, make
sure that the total power consumption of all
connected devices does not exceed the power
strip's maximum throughput rating.
If you will not be using the product for a
prolonged period, disconnect it from mains
power.
Unless different instructions have been expressly
given in the operating instructions for the devices
you are charging, proceed as fol lows:
Connect your device to a USB charging socket
using a suitable USB cable.
Connect the charger to a properly installed and
easily accessible mains socket.
The charging process is displayed on your device.
Disconnect the device from the charger if you wish
to interrupt the charging process or when the
device is fully charged.
Then disconnect the charger from the line
connection.
When charging the rechargeable batteries in the
device, note the maximum charging times for the
built-in batteries.
5. Care and maintenance
Only use soft, dry towels to clean the product.
Note
Disconnect the device from the mains before
cleaning and during prolonged periods of
non-use.
6. Technical data
Specications according to
Regulation (EU) 2019/1782
Brand name,
commercial register
number, address
Hama, HRA12159,
Dresdner Str. 9,
86653 Monheim,
Germany
Model identier
00086402, 00125128,
00201649, 00201650
Input voltage 100 240 V
Input AC
frequency
50 / 60 Hz
Output voltage /
output current /
output power total
5.0V DC / 3.0A/ 15.0W
9.0V DC / 2.22A/ 20.0W
12.0V DC / 1.67A / 20.0 W
Average eciency
during operation
81.4%
Eciency at low load
(10%)
80.7%
Power consumption
at zero load
0.10W
7. Warranty disclaimer
Hama GmbH & Co KG assumes no liability and
provides no warranty for damage resulting from
improper installation/mounting, improper use of
the product or from failure to observe the operating