Instruction Manual

3
5. Connection
Warning
•Only operate the product from asocket that has been
approved for the device. The socket must be installed close
to the product and must be easily accessible.
•Disconnect the product from the power supply using the On/
Off switch –ifthis is not available, unplug the power cord
from the socket.
•Ifusing amulti-socket power strip, make surethat the total
power consumption of all connected devices does not exceed
the power strip's maximum throughput rating.
•Ifyou will not be using the product for aprolonged period,
disconnect it from mains power.
All devices must be switched off beforedevices can be connected.
The overvoltage protector may be connected only between the
electrical consumer and an earthed socket. In the operational state,
the indicator light for the overvoltage protector lights up.
Warning
If the indicator light is not lit after switching on, the overvoltage
protector is defective –itmay no longer be used and must be
exchanged for anew overvoltage protector.
6. Careand Maintenance
Note
Disconnect the device from the power supply beforecleaning it
or if it is not going to be used for along period of time.
•Only clean this product with aslightly damp, lint-free cloth and
do not use aggressive cleaning agents.
•Make surethat water does not get into the product.
7. Warranty Disclaimer
Hama GmbH &Co. KG assumes no liability and provides no
warranty for damage resulting from improper installation/mounting,
improper use of the product or from failuretoobserve the operating
instructions and/or safety notes.
8. Insurance cover of 20 million euros
Our product liability insurance provides cover of up to 20 million
euros for personal injury and damage to property.The prerequisites
areproper product use (please note the safety information) and
proof that the damage is attributable to non-compliance with the
described protective function (please see the technical specications
on the type plate and in these operating instructions).
9. Technical Data
Overvoltage
protection
Up: L-N=1,5kV;L/N-PE=2,0kV;
Uc: 255V~ 50Hz
Uoc: L-N=5,0kV;L/N-PE=6,0kV;
Type III /T3
Total
leakage current
18.000 A(3x6.000A)
Cable length 1.4 m
Mains supply 250 V/50-60 Hz /16A
Cable cross-
sectional area
1.5 mm
2
Connected load
max. 3680 W
10. Recycling Information
Note on environmental protection:
After the implementation of the European Directive
2012/19/EU and 2006/66/EU in the national legal
system, the following applies: Electric and electronic
devices as well as batteries must not be disposed of
with household waste. Consumers areobliged by law
to return electrical and electronic devices as well as batteries at the
end of their service lives to the public collecting points set up for
this purpose or point of sale. Details to this aredened by the
national law of the respective country.This symbol on the product,
the instruction manual or the package indicates that aproduct is
subject to these regulations. By recycling, reusing the materials or
other forms of utilising old devices/Batteries, you aremaking an
important contribution to protecting our environment.