User Manual

Features
Hardware Features
Combined Oscilloscope, Data Logger, Signal Generator, Spectrum Analyzer, Voltage
Meter and Frequency Meter functions
12-Bit ADC Resolution
12-Bit data streaming simultaneously on both channels
32k Byte Waveform buffer
Sampling Rate
Oscilloscope – 20MS/s (repetitive) , 1MS/s native
Data logger – up to 50kS/s
Maximum input voltage +/- 50V DC (35V RMS AC)
AC/DC coupling
Edge min / max, pulse width and delayed trigger modes
Analog Bandwidth 250KHz
Inbuilt 10-bit waveform generator with +/- 3.5V output range and 1k buffer
Bus Powered USB Interface (250mA)
Instrument carrying bag included
Attractive enclosure with rubberized mouldings
Dimensions – W: 116mm x H: 30mm x D: 100mm
Weight: 160g (excluding cable)
Easy Scope II Software Features
Timebase – 2us / div to 50ms / div in 14 steps
Y-Scale 10mV / div to 5V / div
On screen X and Y measurement cursors
FFT Spectrum Analyser display on both channels
Meter displays – Min, Max, Mean, True RMS Voltage and Frequency
Save results to CSV file
Save screen to BMP file
Waveform generation – Sine, Square, Triangle, Sawtooth and user defined waveforms
Easy Logger Software Features
Sampling Rate selectable from >100,000 samples / sec to 100 sec/sample
Flexible Y-axis scaling (V, mV, User Defined)
Flexible X-axis scaling (Sample Number or Time)
Save to CSV, BMP. TXT or Binary files
Up to 3 on-screen cursors to track data
Up to 4 pop-up or email alerts
Text memos for incorporating user notes in the data
Getting Started
The Haltech Stingray 2 Channel USB Oscilloscope requires device drivers to be
installed on your PC to enable communication with the instrument. Install the device
drivers prior to installing the applications below.
Driver Installation
The latest device drivers are available through the Microsoft Windows Update service.
Simply plug in the Haltech Stingray 2 Channel USB Oscilloscope via the USB Cable
provided in the kit. When the Found New Hardware wizard appears, allow it to find the
drivers from the windows update service. Windows 7 defaults to automatically download
the drivers without prompts.
The Haltech Stingray 2 Channel USB Oscilloscope utilizes a 2-Channel FTDI chip, so
the wizard will re-appear a second time to install the drivers for the second channel.
On completion of installation the device I ready to use.
Application Installation
Easy Scope II
The Easy Scope II application file is found on the software page on the Haltech
Resource CD, Click on the Easy Scope II software link to start the installation.
Follow the on screen prompts to install the application.
Easy Logger
The Easy Logger application file is found on the software page on the Haltech
Resource CD, Click on the Easy Logger software link to start the installation.
Follow the on screen prompts to install the application.
Once installed the applications can be accessed through the Windows start menu