Specification Sheet

Printed in the U.S.A.
S300-2E-Q, S500-5E-Q,
S1000-10E-Q, S-L/R
Economy Free-Standing
Cooler
(CONTINUED)
PLUMBING CONNECTIONS
Enter directly into cabinet. Waste 1
1
/4".
Supply
3
/8" tubing.
Trap and service stop not included.
OPERATING PRESSURES
Supply water-105 psi maximum
ELECTRICAL
Furnished with plug-in, 3-wire grounding type
service cord. Standard 120 volt, 60 Hz, single
phase. Transformers available for other power
supplies. (See capacity chart for amp rating.)
Install 120-volt receptacle, rated at 15-amp
minimum to receive 3-wire parallel blade
grounding type male plug.
Note: Installation outdoors in an unprotected
environment is not recommended.
SIDE VIEWFRONT VIEW
NOTE: A service supply stop must be installed at the cooler inlet line.
A = Recommended water supply location 3/8" O.D. unplated copper tube connect stub 1-1/2" (38mm) out from wall shut off by others
B = Recommended location for waste outlet 1-1/4" O.D. drain
C = 1-1/4" Trap not furnished
D = Electrical supply (3) wire recessed box
E = Insure proper ventilation by maintaining 4" (102mm) (Min.) Clearance from cabinet louvers to wall