Spec Sheet
B
D
C
E
F
H
G
WATER INLET
DRAIN INLET
A
A
14
9/1
6"
3
71m
m
3"
76m
m
10"
254mm
8"
203mm
3
0"
762mm
44"
1118mm
6
4"
16
26m
m
4"
102mm
FROST
LINE
5 CUBIC FEET
POROUS FILL
( LARGE BROKEN FILL
)
DRAIN LINE BY INSTALLER
( AS REQUIRED BY LOCAL CODES )
WATER INLET LINE
( BY INSTALLER )
CONCRETE SLAB
BACK FILL
( DIRT )
21"
533mm
MIN.
F
ROST LINE DEPTH
D
EPENDANT ON
G
EOGRAPHIC
L
OCATION AND
L
OCAL
R
EQUIREMENTS
12"
305mm
FILL LINE
MIN.
(6)1/2" (13mm) DIA. HOLES
EQUALLY SPACED ON A
12" (305mm) BOLT CENTER
PVC COLUMN CENTERED
BETWEEN MOUNTING
BOLT HOLES
E
F
G
Printed in the U.S.A.
Page 2
OPERATING PRESSURES:
Supply water 20 – 105 psi maximum
TOP VIEW
®
halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, Oak Brook, IL 60523
Endura II™ Outdoor Tubular
Freeze-Resistant
Bottle Filling Station
MODEL 4400BFFRK
MOUNTING INSTRUCTIONS and
PLUMBING INSTRUCTIONS
Site and drainage excavation is required for fountain installation. Refer
to owner’s manual for site preparation details. Provide solid, well-drained
smooth, at, nished surface to mount pedestal fountain (concrete pad
recommended) with adequate support (300 lb. load minimum). (6) 3/8”
minimum fasteners (not included) should be attached securely to mounting
surface in order to secure fountain, (Refer to rough-in diagram), and be
sure to allow an opening for the freeze-resistant valve in the ground as
shown in the installation instructions that accompany the fountain. (Refer
to the rough-in diagram below). Refer to local codes for any additional
requirements.
Locate and install plumbing through ground as required. Assemble
fountain to prepared site and mounting pad.
NOTE: Fountain is not furnished with service valve.
Position pedestal over plumbing and secure base to fasteners. Remove
access panels and connect supply and water lines. Turn on water supply
and check for leaks. Refer to owner’s manual for detailed instructions.
Reassemble access panels to pedestal.
Trap and service stop not included.
SITE PREPARATION
DETAIL
LEGEND
A = ACCESS PANEL (8” X 10”)
B = 1” PVWC DRAIN
C = PRESSURE FITTING 1-1/4” x 3/4”
D = CONNECTOR 1-1/4” to 1-1/4”
E = 1-1/4” DRAIN TUBE
F = AIR CONTROL LINE
G = 1/4” WATER LINE
H = CONNECTOR FOR AIR CONTROL LINE
SIDE & FRONT VIEWS
36” Minimum
67” Maximum
DRAIN LINE