Instructions / Assembly
HEATER STAND AND LOCATION
The heater is primarily for outdoor use only. Always ensure that
adequate fresh air venlaon is provided.
Always maintain proper clearance to combusble materials, i.e.
top 153 cm and sides 122 cm minimum.
Heater must be placed on level firm ground.
Never operate heater in an explosive atmosphere like in areas
where gasoline or other flammable liquids or vapors are stored.
122 CM
153 CM
WALL
CEILING
Use propane, butane or their mixtures gas only.
The pressure regulator and hose assembly to be used must conform to local standard codes.
The installaon must conform to local codes, or in the absence of local codes, with the standard for
the storage and handling of liquid petroleum gases.
A dented, rusted or damaged tank may be hazardous and should be checked by your tank supplier.
Never use a tank with a damaged valve connecon.
The tank must be arranged to provide for vapor withdrawal from the operang cylinder.
Never connect an unregulated tank to the heater.
GAS REQUIREMENTS
LEAKAGE TEST
Gas connecons on the heater are leak tested at the factory prior to shipment. A complete gas ght-
ness check must be performed at the installaon site due to possible mishandling in shipment or
excessive pressure being applied to the heater.
Make a soap soluon of one part liquid detergent and one part water, The soap soluon can be
applied with a spray bole, brush or rag. Soap bubbles will appear in case of a leak.
The heater must be checked with a full cylinder.
Make sure the safety control valve is in the OFF posion.
Turn the gas supply ON.
In case of a leak, turn off the gas supply. Tighten any leaking fings, then turn the gas supply on
and re-check.
Never leak test while smoking.
8