Instructions / Assembly

A. Construction and characteristics
Transportable terrace/fire pit with tank housing
Casing in steel with powder-coang or stainless steel.
Gas hose connecons with metal clamp
B. Specifications
Use propane,butane or their mixtures gas only.
Max. waage:50000BTU/Hr(14.65KW)
Consumpon:
The hose and regulator assembly must conform to local standard codes.
Regulator outlet pressure should meet the corresponding appliance
category in B. Specificaon.
The appliance requires approved hose in 0.7m length.
a)When an appliance is for connecon to a fixed piping system,the installaon must conform with local
codes,or in the absence of local codes with the Naonal Fuel Gas Code,ANSI Z223.1•NFPA 54;Naonal
Fuel Gas Code;Natural Gas and Propane Installaon Code,CSA B149.1;or Propane Storage and Handing
Code,CSA B149.2,as applicable;
b)A statement that solid fuels shall not be burned in this appliance;
c)The minimum inlet gas supply pressure: 25 Psi;
d)The maximum inlet gas supply pressure: 250 Psi;
Instrucons to keep the appliance area clear and free from combusble materials,gasoline,and other
flammable vapors and liquids;
10
The instrucons accompanying the appliance shall include the following;