Specification
13
By-pass
regula-
ting
 Figure 14b (DUAL)
AUX AUX
 Figure 13   Figure 14a
ADJUSTING THE MINIMUM GAS FLOW
When installing the cooker you must check that the minimum gas fl ow of the burners on the hob and in the oven is 
correctly regulated. If the type of gas is changed it is indispensable to adjust the minimum fl ow. The regulating procedure 
is as follows.
A) Burners on the hob (fig. 13)
1.  Light one burner at a time and turn the flame up to maximum.
2. Remove the knob of the corresponding gas tap and insert screwdriver in the screw as showed in figure 
14a or 14b (DUAL).
3.  Turn the tap to minimum position.
4.  Unscrew, turning to the left, to increase the flame, or screw to the right to decrease it.
5.  If a liquid gas is used (Butane - Propane), the regulating screw must be fully screwed in.
SERVICE & MAINTENANCE INSTRUCTIONS
Replacement Parts.
Authorized replacement parts may be used in performing service on the appliance. Replacement parts are available 
from factory authorized part distributors.
Service and maintenance only to be carried out by an authorised person.
To replace parts such burners, valves and electric components, the hotplate must be removed from the bench 
top by releasing the attachment hooks, loosening the attachment screws of each burner, unscrewing the hotplate 
attachments nuts which are visible at the bottom of the surface, removing the hotplate top and fi nally replacing the 
defective parts.
Note: if the valves must be replaced, fi rst disassemble the ignitions switches wires.
It is recommended to replace the valve gaskets each time the valve is replaced.
WARNING: After first installation of the appliance or after any service intervention concerning main gas parts of the 
appliance, make the leak test using water with soap an the gas connections in order to verify the correct installation. 
Do not use fire for gas leak testing.
NON WORKING APPLIANCES
Before calling the After Sales Service, check that the appliance is connected or that the main switch is activated. 
After, call the After Sales Service. The faults must be checked by a skillfull technician.
Remark: the appliance is equipped with a safety thermostat, adjusted at a certain temperature. In case it reaches a 
higher temperature, the appliance switches off .