Hallman Installation Guide and Users Manual
Ceiling 
Height
Venting Requirements
Page 5
Height & Clearance
Under Cabinet 
Range hood
36” 
Counter 
Top
Min:
27” 
Max: 30”
Vent  system  must  terminate  to  the  outside • 
(roof or side wall).
DO NOT terminate the vent system in an at-• 
tic or other enclosed area.
DO NOT use 4” (10.2 cm) laundry-type wall • 
caps.
Use metal/aluminum vent only. Rigid metal/• 
aluminum vent is recommended.
DO NOT use plastic vent.• 
Always keep the duct clean to ensure proper • 
airow.
Calculate the following gures before instal-• 
lation:
Distance from the oor to the ceiling.1. 
Distance between the oor to the coun-2. 
tertop/stove (recommend* 27” to 30”).
Distance  between  the  countertop/stove 3. 
to the range hood.
Height of hood and duct cover.4. 
For the most efcient & quiet operation:
A distance of 27” to 30” is recommended* • 
between stove top and the bottom of range 
hood.
It  is  recommended  that  the  range  hood  be • 
vented vertically through the roof through 8” 
(17.8 cm)  or  bigger  round  metal/aluminum 
vent work.
The size of the vent should be uniform.• 
Use no more than three 90° elbows.• 
Make  sure  there  is  a  minimum  of  24”  (61 • 
cm)  of  straight  vent  between  the  elbows  if 
more than one elbow is used.
DO NOT install two elbows together.• 
The  length  of  vent  system  and  number  of • 
elbows should be kept to a minimum to pro-
vide efcient performance.
The vent system must have  a damper. If • 
roof  or  wall  cap  has  a  damper,  DO  NOT 
use damper (if supplied) on top of the range 
hood.
Use silver tape or duct tape to seal all joints • 
in the vent system.
Use  caulking  to  seal  exterior  wall  or  roof • 
opening around the cap.
* Due to different ceiling height congurations, rec-
ommended height may not be applicable.
Cabinet or Single-
piece Chimney 
(Optional)
Range 
Hood 
Height
Cabinet 
Height
Countertop/Stove