CAFS Air Bottle Installer/Operation Guide
p/n: 029-0020-85-0
Installer Installation
Add a service loop to avoid strain on the wires or connectors during body
and frame flex. Also see Figure 4-17: “Extra Cable Storage” on page 43.
CAFSAttack Main Wire Harness
The system installer must provide an extension main power and ground
wire cable for the Class1 CAFSAttack system. (See heading Primary
Power and Ground” on page 42.) Also see Figure 4-16: “Primary CAFS
Wire Harness.
Figure 4-16: Primary CAFS Wire Harness
Before connecting the cable harness, Class1 p/n: 112757, inspect the O-
ring seals of the female connectors. If a seal washer is missing or dam-
aged, water can enter the connector causing pin and terminal corrosion,
resulting in possible system failure.
IMPORTANT !
THE POWER MUST BE FUSED FOR 12 VDC (OR OPTIONAL 24 VDC), MINI-
MUM 20 AMP. CIRCUIT TO MEET NFPA SPECIFICATIONS. USE MINIMUM 16
AWG TYPE SXL OR GXL (SAE J1128) WIRE.
DO NOT CONNECT POWER SUPPLY HARNESS TO A “LOAD SHEDDING
SYSTEM.