Introduction
A “FILL” required signal is then generated in the Class 1 Driver Module to
begin the FILL process. The driver module incorporates an auto-fill function
that, when activated, OPENS the SVS valve at less than 75% tank level and
CLOSES the valve when the tank reaches the FULL point (approximately
1/8 of volume from FULL).
An optional alarm is available and activates when the tank drops to 1/4
FULL, or if data is lost for more than ten seconds.
Also see High Current 4-Light Remote Driver Module Manual, p/n: 107451,
for more detailed information. This manual is provided as a separate
attachment, located at the back of this manual.
Relay Assembly
The relay assembly (Hale p/n: 513-0545-00-0) reads the toggle switch set-
ting on the AutoFill select panel, placing the system in either the AUTO or
MANUAL mode.
In AUTO, the relay assembly receives the FILL required signal from the
driver module and controls the SVS valve accordingly.
In MANUAL, the SVS valve is controlled by the manual control panel.
Also see heading “MANUAL Control Panel” on page 12.
2.4 AUTOFILL CONTROL PANELS
AUTOFILL Control Panel
(See Figure 2-3: “AutoFill Control
Panel AUTO / MANUAL.”)
Toggle Switch
The toggle switch places the
AUTOFILL system in either the
AUTO or MANUAL mode of oper-
ation.
Note: When placed in the MANUAL
mode, this panel operates in conjunction with the Manual Control Panel - see
heading “MANUAL Control Panel” on page 12.
Figure 2-3: AutoFill Control Panel
AUTO / MANUAL