Product Manual

– 5 –
2690197
P/N’S 1821212, 1821213, 1821214, 1821215, 1821216
1400 N
1200 N
1000 N
800 N
600 N
400 N
1400 N
1200 N
1000 N
800 N
600 N
400 N
15° 15°
30° 30°
45° 45°
60° 60°
75° 75°
90°
105°
120°
90°
105°
120°
135° 135°
150° 150°
165° 165°
180° 180°
195° 195°
210° 210°
225° 225°
240° 240°
255° 255°
270° 270°
285° 285°
300° 300°
315° 315°
330° 330°
345° 345°
P 1
S
P 1
S
Allowable radial load and axial load at drive shaft (w/o reinforced front bearing)
Allowable radial load P
S
dependent on di-
rection of force related to motor for counter
clockwise rotation, code L.
Allowable radial load P
S
dependent on di-
rection of force related to motor for counter
clockwise rotation, code R.
Maximum allowable axial force for
both directions
P
T
= 700 Nm (6196 lbf in) at vis-
cosity of 10 cSt (59SSU).
Sum of P
T
+ P
S
does not exceed
1050 Nm (9293 lbf in) if appear
simultaneously.
Radial pre-load used at V-belt
drive is not permissable for  uid
motors w/o reinforced front bear-
ing.
25
Size Curve PS1
< “p (bar/psi)
080 -8.0cc 276/4000
110 -11.0cc 276/4000
160 -16.0cc 200/2900
190 -19.0cc 160/2300
230 -23.0cc 160/2300
1 Newton = .224 pound-force (lbf)
400 Newtons = 89.92 pound-force (lbf)
* CASE DRAIN MUST BE USED. OUTLET PRESSURE ON A UNIDIRECTIONAL MOTOR OR CASE DRAIN PRESSURE ON A
BIROTATIONAL MOTOR MUST NOT EXCEED SEAL PRESSURE RATINGS.
Important Note: The data below shows maximum values and cannot be used concurrently, e.g. the maximum operating pressure depends on material
type, shaft speed and temperature. Contact your Concentric representative for additional information.
27.5 for  ange options
10/11 and 12/13.
Description Max. Pressure PSI (BAR) Temperature °F (°C)
Cont. Inter. Min. Max.
High Pressure Viton 87 (6) 116 (8) -4 (-20) 221 (105)
The butter y curves below show allowable radial loads based on motor location at any angle of orientation. You should not exceed
the limit on the outer pro le of the curve (green), based on motor location at any angle of orientation. Consult Concentric Hydraulics
when using operating pressures greater than the P
S
1 pressures noted in the chart below. N represents newtons.