Specification

Round LED High Bay Series
RHB200_840_UNV_W with 60 DEG
aluminum reector
RHB200_840_UNV_W 10121
RHB200_840_UNV_W with 70 DEG
polycarbonate reector
RHB200_840_UNV_W with 90 DEG
aluminum reector
Photometrics
RHB150
RHB200
4.16"
(105.6mm)
4.16"
(105.6mm)
11.8"
(299.9mm)
9.4"
(238.9mm)
6.57"
(167.4mm)
11.8"
(299.9mm)
9.4"
(238.9mm)
6.57"
(167.4mm)
11.8"
(299.9mm)
4.16"
(105.6mm)
11.8"
(299.9mm)
11.8"
(299.9mm)
6.67"
(169.4mm)
9.4"
(238.9mm)
11.8"
(299.9mm)
6.67"
(169.4mm)
9.4"
(238.9mm)
4.16"
(105.6mm)
CD: 0
1,617
3,233
4,850
6,467
8,083
9,700
50°
60°
70°
80°
90°
40°30°20°10°VA:
0° H =
90° H =
CD: 0
4,333
8,667
13,000
17,333
21,667
26,000
50°
60°
70°
80°
90°
40°30°20°10°VA:
0° H =
90° H =
CD: 0
3,500
7,000
10,500
14,000
17,500
21,000
50°
60°
70°
80°
90°
40°30°20°10°VA:
0° H =
90° H =
CD: 0
2,667
5,333
8,000
10,667
13,333
16,000
50°
60°
70°
80°
90°
40°30°20°10°VA:
0° H =
90° H =
ZONAL LUMEN SUM MARY
ZONE LUMENS % LAMP % LUMINAIRE
0-30
7,610.8 28.3% 28.3%
0-40
12,563.1 46.7% 46.7%
0-60
22,303.9 83% 83%
60-90
4,468.7 16.6% 16.6%
70-100
1,350.4 5% 5%
90-120
26.5 0.1% 0.1%
0-90 26,772.6 99.6% 99.6%
90-180
107.7 0.4% 0.4%
0-180
26,880.3 100% 100%
LUM ENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
0-10
914.8 3.4%
90-100
4.2 0%
10-20
2,642.2 9.8%
100-110
8.6 0%
20-30
4,053.8 15.1%
110-120
13.6 0.1%
30-40
4,952.2 18.4%
120-130
17.3 0.
1%
40-50
5,154.2 19.2%
130-140
18.9 0.1%
50-60
4,586.7 17.1%
140-150
17.7 0.1%
60-70
3,122.6 11.6%
150-160
14.4 0.1%
70-80
1,223.3 4.6%
160-170
9.5 0%
80-90
122.8 0.5%
170-180
3.4 0%
ROADWAY SUMM ARY
CUTOFF CLASSIFICATION:
CUTOFF
DISTRIBUTION:
TYPE VS
MAX CD, 90 DEG VERT:
3.4
MAX CD, 80 TO < 90 DEG:
432.0
LUMENS % LAMP
DOWNWARD STREET SIDE:
13,308.1 49.5%
DOWNWARD HOUSE SIDE:
13,467.5 50.1%
DOWNWARD TOTAL:
26,775.6 99.6%
UPWARD STREET SID
E:
56.7 0.2%
UPWARD HOUSE SIDE:
51.0 0.2%
UPWARD TOTAL:
107.7 0.4%
TOTAL LUMENS: 26,883.4 100%
LCS TABLE
BUG RATI NG
B4 - U3 - G2
FORWARD LI GHT
LUMENS LUMENS %
LOW(0-30): 3,800.9 14
.1%
MEDIUM(30-60): 7,315.3 27.2%
HIGH(60-80): 2,133.9 7.9%
VERY HIGH(80-90): 57.9 0.2%
BACK LI GHT
LOW(0-30): 3,810.0 14.2%
MEDIUM(30-60): 7,380.7 27.5%
HIGH(60-80): 2,211.9 8.2%
VERY HIGH(80-90): 64.9 0.2%
UPLI GHT
LOW(90-100): 4.2 0%
HIGH(100-180): 103.5 0.4%
TRAPPED
LI GHT:
0.000 0%
ZONAL LUMEN SUM MARY
ZONE LUMENS % LAMP % LUMINAIRE
0-30
7,610.8 28.3% 28.3%
0-40
12,563.1 46.7% 46.7%
0-60
22,303.9 83% 83%
60-90
4,468.7 16.6% 16.6%
70-100
1,350.4 5% 5%
90-120
26.5 0.1% 0.1%
0-90 26,772.6 99.6% 99.6%
90-180
107.7 0.4% 0.4%
0-180
26,880.3 100% 100%
LUM ENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
0-10
914.8 3.4%
90-100
4.2 0%
10-20
2,642.2 9.8%
100-110
8.6 0%
20-30
4,053.8 15.1%
110-120
13.6 0.1%
30-40
4,952.2 18.4%
120-130
17.3 0.
1%
40-50
5,154.2 19.2%
130-140
18.9 0.1%
50-60
4,586.7 17.1%
140-150
17.7 0.1%
60-70
3,122.6 11.6%
150-160
14.4 0.1%
70-80
1,223.3 4.6%
160-170
9.5 0%
80-90
122.8 0.5%
170-180
3.4 0%
ROADWAY SUMM ARY
CUTOFF CLASSIFICATION:
CUTOFF
DISTRIBUTION:
TYPE VS
M
AX CD, 90 DEG VERT:
3.4
MAX CD, 80 TO < 90 DEG:
432.0
LUMENS % LAMP
DOWNWARD STREET SIDE:
13,308.1 49.5%
DOWNWARD HOUSE SIDE:
13,467.5 50.1%
DOWNWARD TOTAL:
26,775.6 99.6%
UPWARD STREET SID
E:
56.7 0.2%
UPWARD HOUSE SIDE:
51.0 0.2%
UPWARD TOTAL:
107.7 0.4%
TOTAL LUMENS: 26,883.4 100%
LCS TABLE
BUG RATI NG
B4 - U3 - G2
FORWARD LI GHT
LUMENS LUMENS %
LOW(0-30): 3,800.9 14.1%
MEDIUM(30-60): 7,315.3 27.2%
HIGH(60-80): 2,133.9 7.9%
VERY HIGH(80
-90): 57.9 0.2%
BACK LI GHT
LOW(0-30): 3,810.0 14.2%
MEDIUM(30-60): 7,380.7 27.5%
HIGH(60-80): 2,211.9 8.2%
VERY HIGH(80-90): 64.9 0.2%
UPLI GHT
LOW(90-100): 4.2 0%
HIGH(100-180): 103.5 0.4%
TRAPPED
LI GHT:
0.000 0%
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % LUMINAIRE
0-30
15,021.6 62.1% 62.1%
0-40
20,217.4 83.6% 83.6%
0-60
24,034.6 99.3% 99.4%
60-90
58.1 0.2% 0.2%
70-100
21.9 0.1% 0.1%
90-120
6.4 0% 0%
0-90 24,092.7 99.6% 99.6%
90-180
94.3 0.4% 0.4%
0-180
24,187.0 100% 100%
LUMENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
0-10
2,362.1 9.8%
90-100
1.0 0%
10-20
6,353.9 26.3%
100-110
1.3 0%
20-30
6,305.6 26.1%
110-120
4.1 0%
30-40
5,195.8 21.5%
120-130
8.9 0%
40-50
3
,162.8 13.1%
130-140
14.8 0.1%
50-60
654.4 2.7%
140-150
19.9 0.1%
60-70
37.2 0.2%
150-160
21.4 0.1%
70-80
16.6 0.1%
160-170
16.5 0.1%
80-90
4.3 0.0%
170-180
6.4 0%
ROADWAY SUMMARY
CUTOFF CLASSIFICATION:
CUTOFF
DISTRIBUTION:
TYPE VS
MAX CD, 90 DEG VERT:
1.1
MAX CD, 80 TO <90 DEG:
9.7
LUMENS % LAMP
DOWNWARD STREET SIDE:
11,938.4 49.3%
DOWNWARD HOUSE SIDE:
12,160.2 50.3%
DOWNWARD TOTAL:
24,098.5 99.6%
UPWARD STREET SIDE:
50.8 0.2%
UPWARD HO
USE SIDE:
43.6 0.2%
UPWARD TOTAL:
94.4 0.4%
TOTAL LUMENS: 24,192.9 100%
LCS TABLE
BUG RATING
B5 - U3 - G0
FORWARD LIGHT
LUMENS LUMENS %
LOW(0-30): 7,467.5 30.9%
MEDIUM(30-60): 4,442.3 18.4%
HIGH(60-80): 26.4 0.1%
VERY HIGH(80-90): 2.1 0%
BACK LIGHT
LOW(0-30): 7,556.8 31.2%
MEDIUM(30-60): 4,573.8 18.9%
HIGH(60-80): 27.3 0.1%
VERY HIGH(80-90): 2.2 0%
UPLIGHT
LOW(90-100): 1.0 0%
HIGH(100-180): 93.4 0.4%
TRAPPED LIGHT:
0.1 0%
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % LUMINAIRE
0-30
15,021.6 62.1% 62.1%
0-40
20,217.4 83.6% 83.6%
0-60
24,034.6 99.3% 99.4%
60-90
58.1 0.2% 0.2%
70-100
21.9 0.1% 0.1%
90-120
6.4 0% 0%
0-90 24,092.7 99.6% 99.6%
90-180
94.3 0.4% 0.4%
0-180
24,187.0 100% 100%
LUMENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
0-10
2,362.1 9.8%
90-100
1.0 0%
10-20
6,353.9 26.3%
100-110
1.3 0%
20-30
6,305.6 26.1%
110-120
4.1 0%
30-40
5,195.8 21.5%
120-130
8.9 0%
40-50
3
,162.8 13.1%
130-140
14.8 0.1%
50-60
654.4 2.7%
140-150
19.9 0.1%
60-70
37.2 0.2%
150-160
21.4 0.1%
70-80
16.6 0.1%
160-170
16.5 0.1%
80-90
4.3 0.0%
170-180
6.4 0%
ROADWAY SUMMARY
CUTOFF CLASSIFICATION:
CUTOFF
DISTRIBUTION:
TYPE VS
MAX CD, 90 DE
G VERT:
1.1
MAX CD, 80 TO <90 DEG:
9.7
LUMENS % LAMP
DOWNWARD STREET SIDE:
11,938.4 49.3%
DOWNWARD HOUSE SIDE:
12,160.2 50.3%
DOWNWARD TOTAL:
24,098.5 99.6%
UPWARD STREET SIDE:
50.8 0.2%
UPWARD HO
USE SIDE:
43.6 0.2%
UPWARD TOTAL:
94.4 0.4%
TOTAL LUMENS: 24,192.9 100%
LCS TABLE
BUG RATING
B5 - U3 - G0
FORWARD LIGHT
LUMENS LUMENS %
LOW(0-30): 7,467.5 30.9%
MEDIUM(30-60): 4,442.3 18.4%
HIGH(60-80): 26.4 0.1%
VERY HIGH(80-90): 2.1 0%
BACK LIG
HT
LOW(0-30): 7,556.8 31.2%
MEDIUM(30-60): 4,573.8 18.9%
HIGH(60-80): 27.3 0.1%
VERY HIGH(80-90): 2.2 0%
UPLIGHT
LOW(90-100): 1.0 0%
HIGH(100-180): 93.4 0.4%
TRAPPED LIGHT:
0.1 0%
ZONAL LUM EN SUM MARY
ZONE LUMENS % LAMP % LUMINAIRE
0-30
14,347.5 59% 59%
0-40
18,795.3 77.2% 77.3%
0-60
21,886.7 89.9% 90%
60-90
1,654.5 6.8% 6.8%
70-100
1,123.6 4.6% 4.6%
90-120
501.6 2.1% 2.1%
0-90 23,541.2 96.7% 96.8%
90-180
787.0 3.2% 3.2%
0-180
24,328.2 100% 100%
LUM ENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
0-10
1,825.2 7.5%
90-100
250.1 1%
10-20
5,307.1 21.8%
100-110
166.1 0.7%
20-30
7,215.3 29.7%
110-120
85.4 0.4%
30-40
4,447.8 18.3%
12
0-130
64.8 0.3%
40-50
1,782.8 7.3%
130-140
61.7 0.3%
50-60
1,308.6 5.4%
140-150
59.2 0.2%
60-70
781.0 3.2%
150-160
51.0 0.2%
70-80
489.3 2.0%
160-170
35.8 0.1%
80-90
384.2 1.6%
170-180
12.8 0.1%
ROADWAY SUMM ARY
CUTOFF CLASSIFICATION:
CUTOFF
DISTRIBUTION:
TYPE VS
MAX CD, 90 DEG VERT:
300.0
MAX CD, 80 TO < 90 DEG:
464.5
LUMENS % LAMP
DOWNWARD STREET SIDE:
11,773.6 48.4%
DOWNWARD HOUSE SIDE:
11,772.1 48.4%
DOWNWARD TOTAL:
23,545.6 96.8%
UPWAR
D STREET SIDE:
400.3 1.6%
UPWARD HOUSE SIDE:
386.7 1.6%
UPWARD TOTAL:
787.0 3.2%
TOTAL LUMENS: 24,332.7 100%
LCS TABLE
BUG RATI NG
B5 - U4 - G2
FORWARD LI GHT
LUMENS LUMENS %
LOW(0-30): 7,151
.8 29.4%
MEDIUM(30-60): 3,783.5 15.5%
HIGH(60-80): 641.9 2.6%
VERY HIGH(80-90): 196.4 0.8%
BACK LI GHT
LOW(0-30): 7,197.0 29.6%
MEDIUM(30-60): 3,758.9 15.4%
HIGH(60-80): 628.3 2.6%
VERY HIGH(80-90): 187.8 0.8%
UPLI GHT
LOW(90-100): 250.0 1%
HIGH(100-180): 537
.0 2.2%
TRAPPED LI GHT:
0.4 0%
ZONAL LUM EN SUM MARY
ZONE LUMENS % LAMP % LUMINAIRE
0-30
14,347.5 59% 59%
0-40
18,795.3 77.2% 77.3%
0-60
21,886.7 89.9% 90%
60-90
1,654.5 6.8% 6.8%
70-100
1,123.6 4.6% 4.6%
90-120
501.6 2.1% 2.1%
0-90 23,541.2 96.7% 96.8%
90-180
787.0 3.2% 3.2%
0-180
24,328.2 100% 100%
LUM ENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
0-10
1,825.2 7.5%
90-100
250.1 1%
10-20
5,307.1 21.8%
100-110
166.1 0.7%
20-30
7,215.3 29.7%
110-120
85.4 0.4%
30-40
4,447.8 18.3%
12
0-130
64.8 0.3%
40-50
1,782.8 7.3%
130-140
61.7 0.3%
50-60
1,308.6 5.4%
140-150
59.2 0.2%
60-70
781.0 3.2%
150-160
51.0 0.2%
70-80
489.3 2.0%
160-170
35.8 0.1%
80-90
384.2 1.6%
170-180
12.8 0.1%
ROADWAY SUMM ARY
CUTOFF CLASSIFICATION:
CUT
OFF
DISTRIBUTION:
TYPE VS
MAX CD, 90 DEG VERT:
300.0
MAX CD, 80 TO < 90 DEG:
464.5
LUMENS % LAMP
DOWNWARD STREET SIDE:
11,773.6 48.4%
DOWNWARD HOUSE SIDE:
11,772.1 48.4%
DOWNWARD TOTAL:
23,545.6 96.8%
UPWAR
D STREET SIDE:
400.3 1.6%
UPWARD HOUSE SIDE:
386.7 1.6%
UPWARD TOTAL:
787.0 3.2%
TOTAL LUMENS: 24,332.7 100%
LCS TABLE
BUG RATI NG
B5 - U4 - G2
FORWARD LI GHT
LUMENS LUMENS %
LOW(0-30): 7,151.8 29.4%
MEDIUM(30-60): 3,783.5 15.5%
HIGH(60
-80): 641.9 2.6%
VERY HIGH(80-90): 196.4 0.8%
BACK LI GHT
LOW(0-30): 7,197.0 29.6%
MEDIUM(30-60): 3,758.9 15.4%
HIGH(60-80): 628.3 2.6%
VERY HIGH(80-90): 187.8 0.8%
UPLI GHT
LOW(90-100): 250.0 1%
HIGH(100-180): 537
.0 2.2%
TRAPPED LI GHT:
0.4 0%
ZONAL LUM EN SUM MARY
ZONE LUMENS % LAMP % LUMINAIRE
0-30
12,195.6 50.2% 50.2%
0-40
19,012.1 78.2% 78.2%
0-60
24,078.0 99.1% 99.1%
60-90
124.6 0.5% 0.5%
70-100
42.2 0.2% 0.2%
90-120
8.1 0% 0%
0-90 24,202.5 99.6% 99.6%
90-180
95.1 0.4% 0.4%
0-180
24,297.6 100% 100%
LUM ENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
0-10
1,414.4 5.8%
90-100
1.6 0%
10-20
4,348.1 17.9%
100-110
1.6 0%
20-30
6,433.0 26.5%
110-120
4.9 0%
30-40
6,816.6 28.1%
120-130
11.1 0%
40-5
0
4,171.1 17.2%
130-140
17.5 0.1%
50-60
894.7 3.7%
140-150
20.6 0.1%
60-70
83.9 0.3%
150-160
19.1 0.1%
70-80
32.1 0.1%
160-170
13.6 0.1%
80-90
8.6 0.0%
170-180
5.1 0%
ROADWAY SUMM ARY
CUTOFF CLASSIFICATI ON:
CUTOFF
DISTRIBUTION:
TYPE VS
MAX CD, 90 DEG VERT:
2.8
MAX CD, 80 TO < 90 DEG:
18.9
LUMENS % LAMP
DOWNWARD STREET SIDE:
12,055.6 49.6%
DOWNWARD HOUSE SIDE:
12,150.9 50%
DOWNWARD TOTAL:
24,206.5 99.6%
UPWARD STREET SIDE:
50.8 0.2%
UPWARD H
OUSE SIDE:
44.3 0.2%
UPWARD TOTAL:
95.1 0.4%
TOTAL LUMENS: 24,301.6 100%
LCS TABLE
BUG RATI NG
B5 - U3 - G0
FORWARD LI GHT
LUMENS LUMENS %
LOW(0-30): 6,099.8 25.1%
M
EDIUM(30-60): 5,896.2 24.3%
HIGH(60-80): 55.5 0.2%
VERY HIGH(80-90): 4.1 0%
BACK LI GHT
LOW(0-30): 6,095.9 25.1%
MEDIUM(30-60): 5,990.1 24.6%
HIGH(60-80): 60.5 0.2%
VERY HIGH(80-90): 4.5 0%
UPLI GHT
LOW(90-100): 1.6 0%
HIGH(100-180): 93.5 0.4%
TRAPPED LI GHT:
0.4 0%
ZONAL LUM EN SUM MARY
ZONE LUMENS % LAMP % LUMINAIRE
0-30
12,195.6 50.2% 50.2%
0-40
19,012.1 78.2% 78.2%
0-60
24,078.0 99.1% 99.1%
60-90
124.6 0.5% 0.5%
70-100
42.2 0.2% 0.2%
90-120
8.1 0% 0%
0-90 24,202.5 99.6% 99.6%
90-180
95.1 0.4% 0.4%
0-180
24,297.6 100% 100%
LUM ENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
0-10
1,414.4 5.8%
90-100
1.6 0%
10-20
4,348.1 17.9%
100-110
1.6 0%
20-30
6,433.0 26.5%
110-120
4.9 0%
30-40
6,816.6 28.1%
120-130
11.1 0%
40-5
0
4,171.1 17.2%
130-140
17.5 0.1%
50-60
894.7 3.7%
140-150
20.6 0.1%
60-70
83.9 0.3%
150-160
19.1 0.1%
70-80
32.1 0.1%
160-170
13.6 0.1%
80-90
8.6 0.0%
170-180
5.1 0%
ROADWAY SUMM ARY
CUTOFF CLASSIFICATI ON:
CUTOFF
DISTRIBUTION:
TYPE VS
MAX CD, 90 D
EG VERT:
2.8
MAX CD, 80 TO < 90 DEG:
18.9
LUMENS % LAMP
DOWNWARD STREET SIDE:
12,055.6 49.6%
DOWNWARD HOUSE SIDE:
12,150.9 50%
DOWNWARD TOTAL:
24,206.5 99.6%
UPWARD STREET SIDE:
50.8 0.2%
UPWARD H
OUSE SIDE:
44.3 0.2%
UPWARD TOTAL:
95.1 0.4%
TOTAL LUMENS: 24,301.6 100%
LCS TABLE
BUG RATI NG
B5 - U3 - G0
FORWARD LI GHT
LUMENS LUMENS %
LOW(0-30): 6,099.8 25.1%
MEDIUM(30-60): 5,896.2 24.3%
HIGH(60-80): 55.5 0.2%
VERY HIGH(80-90): 4.1 0%
BACK LI G
HT
LOW(0-30): 6,095.9 25.1%
MEDIUM(30-60): 5,990.1 24.6%
HIGH(60-80): 60.5 0.2%
VERY HIGH(80-90): 4.5 0%
UPLI GHT
LOW(90-100): 1.6 0%
HIGH(100-180): 93.5 0.4%
TRAPPED LI GHT:
0.4 0%
© 2018 Halco Lighting Technologies, LLC. All rights reserved. Halco and ProLED are registered trademarks of Halco Lighting Technologies. All sizes and specications are subject to change. Online Edition 03-21-18.
Halco Lighting Technologies | 2940 Pacic Drive | Norcross, GA 30071 | Toll Free 800.677.3334 | Phone 770.242.3612 | Fax 800.880.0822 | halcolighting.com | Atlanta | Chicago | Cleveland | Houston | Los Angeles | Phoenix