Specification

Photometrics
CD: 0
1,567
3,133
4,700
6,267
7,833
9,400
50°
60°
70°
80°
90°
40°30°20°10°0°VA:
0° H =
90° H =
CD: 0
1,317
2,633
3,950
5,267
6,583
7,900
50°
60°
70°
80°
90°
40°30°20°10°0°VA:
0° H =
90° H =
CD: 0
1,567
3,133
4,700
6,267
7,833
9,400
50°
60°
70°
80°
90°
40°30°20°10°0°VA:
0° H =
90° H =
© 2018 Halco Lighting Technologies, LLC. All rights reserved. Halco and ProLED are registered trademarks of Halco Lighting Technologies. All sizes and specications are subject to change. Online Edition 03-05-2018.
Halco Lighting Technologies | 2940 Pacic Drive | Norcross, GA 30071 | Toll Free 800.677.3334 | Phone 770.242.3612 | Fax 800.880.0822 | halcolighting.com | Atlanta | Chicago | Cleveland | Houston | Los Angeles | Phoenix
Linear High Bay Series
99650, LHB2/161/850/UNV/LED2
99649, LHB1/111/850/UNV/LED2
0-10
565.7 3.7%
90-100
5.2 0%
10-20
1,601.2 10.6%
100-110
4.1 0%
20-30
2,367.1 15.6%
110-120
5.7 0%
30-40
2,746.0 18.1%
120-130
7.6 0%
40-50
2,711.4 17.9%
130-140
8.3 0.1%
50-60
2,321.1 15.3%
140-150
8.0 0.1%
60-70
1,674.7 11.0%
150-160
6.1 0%
70-80
897.2 5.9%
160-170
3.6 0%
80-90
226.1 1.5%
170-180
1.2 0%
LUMENS LUMENS %
LOW(0-30): 2,290.4 15.1%
MEDIUM(30-60): 3,994.8 26.4%
HIGH(60-80): 1,374.1 9.1%
VERY HIGH(80-90): 137.0 0.9%
BACK LIGHT
LOW(0-30): 2,246.1 14.8%
MEDIUM(30-60): 3,787.9 25%
HIGH(60-80): 1,199.0 7.9%
VERY HIGH(80-90): 89.1 0.6%
UPLIGHT
LOW(90-100): 5.2 0%
HIGH(100-180): 44.6 0.3%
0.000 0%
97.6% 14,791.4 156.5 156.4
67.1% 10,162.7 100.6 101.8
99.7% 15,113.1
4.00 375.29 FC 9.6 9.8 38.5 38.3
8.00 93.82 FC 19.3 19.7 76.9 76.6
12.00 41.70 FC 28.9 29.5 115.4 114.9
16.00 23.46 FC 38.6 39.3 153.8 153.2
20.00 15.01 FC 48.2 49.2 192.3 191.5
100.6° 101.8° 156.5° 156.4°
LUMENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
LCS TABLE
BUG RATING
B1 - U1 - G0
FORWARD LIGHT
TRAPPED LIGHT:
FLOOD SUMMARY
EFFICIENCY LUMENS HORIZONTAL SPREAD VERTICAL SPREAD
FIELD (10%):
BEAM (50%):
TOTAL:
ILLUMINANCE AT A DISTANCE
CENTER BEAM BEAM SPREAD(FT) FIELD SPREAD(FT)
HEIGHT(FT) FOOTCANDLE HORIZONTAL VERTICAL HORIZONTAL VERTICAL
BEAM ANGLE FIELD ANGLE
0-10
842.3 3.7%
90-100
8.0 0%
10-20
2,385.6 10.5%
100-110
5.6 0%
20-30
3,530.3 15.6%
110-120
8.1 0%
30-40
4,102.4 18.1%
120-130
10.2 0%
40-50
4,059.3 17.9%
130-140
11.0 0%
50-60
3,483.4 15.4%
140-150
10.6 0%
60-70
2,519.1 11.1%
150-160
7.9 0%
70-80
1,351.3 6.0%
160-170
4.7 0%
80-90
338.9 1.5%
170-180
1.6 0%
LUMENS LUMENS %
LOW(0-30): 3,418.6 15.1%
MEDIUM(30-60): 6,001.9 26.5%
HIGH(60-80): 2,086.6 9.2%
VERY HIGH(80-90): 211.5 0.9%
BACK LIGHT
LOW(0-30): 3,343.3 14.7%
MEDIUM(30-60): 5,649.4 24.9%
HIGH(60-80): 1,785.5 7.9%
VERY HIGH(80-90): 127.5 0.6%
UPLIGHT
LOW(90-100): 8.0 0%
HIGH(100-180): 59.9 0.3%
0.000 0%
97.7% 22,147.1 156.8 156.4
67.4% 15,275.9 101.4 101.9
99.8% 22,616.3
4.00 558.81 FC 9.8 9.9 39.0 38.3
8.00 139.70 FC 19.5 19.7 77.9 76.6
12.00 62.09 FC 29.3 29.6 116.9 114.9
16.00 34.93 FC 39.1 39.5 155.9 153.2
20.00 22.35 FC 48.8 49.3 194.9 191.5
101.4° 101.9° 156.8° 156.4°
LUMENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
LCS TABLE
BUG RATING
B1 - U1 - G0
FORWARD LIGHT
TRAPPED LIGHT:
FLOOD SUMMARY
EFFICIENCY LUMENS HORIZONTAL SPREAD VERTICAL SPREAD
FIELD (10%):
BEAM (50%):
TOTAL:
ILLUMINANCE AT A DISTANCE
CENTER BEAM BEAM SPREAD(FT) FIELD SPREAD(FT)
HEIGHT(FT) FOOTCANDLE HORIZONTAL VERTICAL HORIZONTAL VERTICAL
BEAM ANGLE FIELD ANGLE
0-10
1,066.6 3.5%
90-100
9.9 0%
10-20
3,044.8 10.1%
100-110
5.5 0%
20-30
4,575.7 15.2%
110-120
7.4 0%
30-40
5,416.4 18.0%
120-130
8.2 0%
40-50
5,447.6 18.1%
130-140
9.3 0%
50-60
4,721.7 15.7%
140-150
9.3 0%
60-70
3,435.0 11.4%
150-160
6.9 0%
70-80
1,857.5 6.2%
160-170
4.5 0%
80-90
476.3 1.6%
170-180
1.7 0%
LUMENS LUMENS %
LOW(0-30): 4,437.0 14.7%
MEDIUM(30-60): 8,101.9 26.9%
HIGH(60-80): 2,856.5 9.5%
VERY HIGH(80-90): 294.6 1%
BACK LIGHT
LOW(0-30): 4,254.1 14.1%
MEDIUM(30-60): 7,491.4 24.9%
HIGH(60-80): 2,438.3 8.1%
VERY HIGH(80-90): 181.9 0.6%
UPLIGHT
LOW(90-100): 9.9 0%
HIGH(100-180): 52.9 0.2%
0.000 0%
97.9% 29,456.8 156.6 158.7
69.9% 21,034.9 101.2 109
99.8% 30,044.6
4.00 705.95 FC 9.7 11.2 38.6 42.5
8.00 176.49 FC 19.5 22.4 77.3 85.1
12.00 78.44 FC 29.2 33.7 115.9 127.6
16.00 44.12 FC 39.0 44.9 154.5 170.2
20.00 28.24 FC 48.7 56.1 193.2 212.7
101.2° 109.0° 156.6° 158.7°
LUMENS PER ZONE
ZONE LUMENS % TOTAL ZONE LUMENS % TOTAL
LCS TABLE
BUG RATING
B1 - U1 - G0
FORWARD LIGHT
TRAPPED LIGHT:
FLOOD SUMMARY
EFFICIENCY LUMENS HORIZONTAL SPREAD VERTICAL SPREAD
FIELD (10%):
BEAM (50%):
TOTAL:
ILLUMINANCE AT A DISTANCE
CENTER BEAM BEAM SPREAD(FT) FIELD SPREAD(FT)
HEIGHT(FT) FOOTCANDLE HORIZONTAL VERTICAL HORIZONTAL VERTICAL
BEAM ANGLE FIELD ANGLE
99651, LHB3/221/850/UNV/LED2
CD: 0
2,000
4,000
6,000
8,000
10,000
12,000
50°
60°
70°
80°
90°
40°30°20°10°0°VA:
0° H =
90° H =
CD: 0
1,500
3,000
4,500
6,000
7,500
9,000
50°
60°
70°
80°
90°
40°30°20°10°0°VA:
0° H =
90° H =
CD: 0
1,500
3,000
4,500
6,000
7,500
9,000
50°
60°
70°
80°
90°
40°30°20°10°0°VA:
0° H =
90° H =
13"
(330mm)
24"
(609mm)
3"
(76mm)
7.2"
(183mm)
LHB1
3"
(76mm)
7.2"
(183mm)
17"
(431mm)
48"
(1219mm)
LHB3
17"
(439mm)
24"
(609mm)
3"
(76mm)
7.2"
(183mm)
LHB2
ZONAL LUMEN SUMMARY
ZONE LUMENS% LAMP
% LUMINAIRE
0-30
4,534.0 29.9% 29.9%
0-40
7,280.1 48% 48%
0-60
12,312.6 81.2% 81.2%
60-90
2,798.0 18.5% 18.5%
70-100
1,128.5 7.4% 7.4%
90-120
15.1 0.1% 0.1%
0-90 15,110.6 99.7% 99.7%
90-180
49.8 0.3% 0.3%
0-180
15,160.4 100% 100%
0-30
6,758.2 29.8% 29.8%
0-40
10,860.6 47.9% 47.9%
0-60
18,403.4 81.2% 81.1%
60-90
4,209.3 18.6% 18.6%
70-100
1,698.2 7.5% 7.5%
90-120
21.7 0.1% 0.1%
0-90 22,612.7 99.7% 99.7%
90-180
67.8 0.3% 0.3%
0-180
22,680.5 100% 100%
ZONAL LUMEN SUMMARY
ZONE LUMENS% LAMP
% LUMINAIRE
0-30
8,687.1 28.9% 28.9%
0-40
14,103.5 46.9% 46.8%
0-60
24,272.8 80.7% 80.6%
60-90
5,768.8 19.2% 19.2%
70-100
2,343.6 7.8% 7.8%
90-120
22.7 0.1% 0.1%
0-90 30,041.5 99.8% 99.8%
90-180
62.8 0.2% 0.2%
0-180
30,104.3 100% 100%
ZONAL LUMEN SUMMARY
ZONE LUMENS% LAMP
% LUMINAIRE
Ambient
Temp.
Rated
Life
77°F(25°C) 110,000 Hours
86°F(30°C) 100,000 Hours
95°F(35°C) 90,000 Hours
104°F(40°C) 80,000 Hours
113°F(45°C) 70,000 Hours
122°F(50°C) 60,000 Hours
131°F(55°C) 50,000 Hours