Operation Manual

54 05-7175-00-00.fm
Maintenance and Servicing
5.3.8 Charging the battery (only 7175.30)
The batteries are charged with the charger Fig. 16-A. The batteries can
already be charged when one segment in the charging status indicator
Fig. 14-51 has gone out.
1. Place the machine on a level surface and turn it off.
2. Disconnect the battery plug Fig. 16-B on the machine.
3. Connect the battery plug of the machine to the charger Fig. 16-C.
4. Switch on the quick-charger. For charging times, please refer to the table,
see section 5.3.7.
5. During the charging process, the battery charging status is displayed in the
display Fig. 16-D of the quick-charger. In the meantime, the charging con-
trol indicator Fig. 14-51 in the display panel is not active!
6. Terminate the charging process:
Switch off the quick-charger
Disconnect the battery plug from the charger and reconnect it to the
machine Fig. 16-E.
Attention
The number of quick charging processes is limited to four a day.
More frequent utilisation may result in excessive heat and
premature failure of the batteries.
Only charge the battery with the supplied quick-charger!
Note
An error is present when the battery symbol flashes in connection
with a field, see operating manual of the charger.
Fig. 16:
AC
B
E