Submittals
Rev. May 2021
SIDE-DISCHARGE AIR CONDITIONER SUBMITTAL
Electrical Requirement
Power Supply
208-230V, 1 Phase, 
60 HZ
Operating Voltage Range 187-253 VAC
Max. Fuse/Breaker Size 15A
MCA 10A
Cooling Performance
Rated Cooling Capacity 17,500 BTU
SEER 14.5
EER 12.0
Operating Range
Cooling 50~115°F (10~46°C)
18,000 BTU 14 SEER SIDE-DISCHARGE AIR CONDITIONER
UUC118WCDA
Pipe Length
Minimum Pipe Length 10 ft
Maximum Pipe Length 82 ft
Maximum Pipe Height Dierence 33 ft
Braze Connection
1/4”(Discharge) 
1/2”(Suction)
Job Name: _______________________________
Purchaser: _______________________________
Submitted To: ____________________________
Construction:  ____________________________
Reference: _______________________________
Approval: ________________________________
Date:  ___________________________________
Submitted By:  ___________________________
Unit:  ___________________________________
Drawing #: _______________________________
Specifications
Compressor Rotary
Uncrated Dimension (HxWxD)
27.6 x 36.0 x 15.0 in
(702 x 914 × 382 mm)
Crated (HxWxD)
30.8 x 38.4 x 16.5 in
(782 x 975 × 420 mm)
Outdoor Sound Rating dB 55
Heat Exchanger Fin Type Aluminum
Weight (Net/Gross) 105.8/123.5 lbs
Factory Refrigerant Charge R-410A (4.7 lbs)
Dimensions (In.)
A B C D E
36.0 15.0 27.6 21.4 12.8
Notice: Federal law allows this unit to be installed only in AK, AL, AR, CO, CT, DC, DE, FL, GA, 
HI, ID, IL, IA, IN, KS, KY, LA, MA, ME, MD, Ml, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NY, OH, OK, 
OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, AND U.S. territories